Light Tower Interpretation ■ Stopping the System
- 68 -
Data I/O ■ 096-0466-001E
Light Tower Interpretation
During operation of the PSV5000 System, you can monitor the light tower to
reduce system down time. The light tower displays the following conditions:
Light
Condition
Action Required
Possible Causes
Machine
Status
Red
Operation
is stopped
due to ma-
jor error or
operator
action
Operator intervention
is mandatory to con-
tinue.
It is likely that tools
and troubleshooting
skills will be required
to resolve issues.
Safety or access door is
open
E-Stop is pushed
Actuator error
Gantry collision
Insufficient air pressure;
Laser not ready
Motion Control System
error
Socket opener sensor
error
Software exception
Vacuum sensor malfunc-
tion
Stopped
Yellow/
Red
(alternat-
ing)
Operation
is stopped
due to
error or
operator
action
Operator intervention
is mandatory to con-
tinue.
Correction may be
through Handler
Computer software
(CH700) or through
minor hardware ad-
justment.
File read/write error
Laser error
No programmer can be
used
PNP error
Serialization errors
Setup related errors
Tape input error
Unprogrammed devices
on Input/Pass tray
Stopped
Yellow
Operation
is stopped
intention-
ally
Operator intervention
is mandatory.
Output media is full or
input media is empty.
The main Start button has
been clicked (the Setup
window is displayed) but
no job is running.
Stopped
Yellow/
Green (al-
ternating)
Running
below
optimum
or
job is
ended
Operator intervention
is suggested.
End of job
Some sockets are disabled
Vacuum errors are pre-
sent on some program-
mers
Processing
or Stopped
(end of job)