Normal overload 110% for 1 minute
IP 20
IP 21
C1
C1
C1
C2
C2
IP 55
C1
C1
C1
C2
C2
IP 66
C1
C1
C1
C2
C2
Mains supply 200 - 240 VAC
Frequency converter
Typical Shaft Output [kW]
P18K
18.5
P22K
22
P30K
30
P37K
37
P450
45
Typical Shaft Output [HP] at 208 V
25
30
40
50
60
Output current
Continuous
(3 x 200-240 V ) [A]
74.8
88.0
115
143
170
Intermittent
(3 x 200-240 V ) [A]
82.3
96.8
127
157
187
Continuous
kVA (208 V AC) [kVA]
26.9
31.7
41.4
51.5
61.2
Max. cable size:
(mains, motor, brake)
[mm
2
/AWG]
50/1/0
95/4/0
120/25
0 MCM
Max. input current
Continuous
(3 x 200-240 V ) [A]
68.0
80.0
104.0
130.0
154.0
Intermittent
(3 x 200-240 V ) [A]
74.8
88.0
114.0
143.0
169.0
Max. pre-fuses
1)
[A]
125
125
160
200
250
Environment
Estimated power loss
at rated max. load [W]
4)
737
845
1140
1353
1636
Weight enclosure IP20 [kg]
Weight enclosure IP21 [kg]
45
45
65
65
65
Weight enclosure IP55 [kg]
45
45
65
65
65
Weight enclosure IP 66 [kg]
45
45
65
65
65
Efficiency
4)
0.96
0.97
0.97
0.97 0.97
VLT
®
HVAC Drive Design Guide
3. VLT HVAC Selection
MG.11.B2.02 - VLT
®
is a registered Danfoss trademark
51
3
Содержание VLT series
Страница 78: ...4 How to Order VLT HVAC Drive Design Guide 78 MG 11 B2 02 VLT is a registered Danfoss trademark 4...
Страница 120: ...7 RS 485 Installation and Set up VLT HVAC Drive Design Guide 120 MG 11 B2 02 VLT is a registered Danfoss trademark 7...
Страница 152: ...8 Troubleshooting VLT HVAC Drive Design Guide 152 MG 11 B2 02 VLT is a registered Danfoss trademark 8...