Normal overload 110% for 1 minute
IP 20
IP 21
B1
B1
B1
B2
IP 55
B1
B1
B1
B2
IP 66
B1
B1
B1
B2
Mains supply 200 - 240 VAC
Frequency converter
Typical Shaft Output [kW]
P5K5
5.5
P7K5
7.5
P11K
11
P15K
15
Typical Shaft Output [HP] at 208 V
7.5
10
15
20
Output current
Continuous
(3 x 200-240 V ) [A]
24.2
30.8
46.2
59.4
Intermittent
(3 x 200-240 V ) [A]
26.6
33.9
50.8
65.3
Continuous
kVA (208 V AC) [kVA]
8.7
11.1
16.6
21.4
Max. cable size:
(mains, motor, brake)
[mm
2
/AWG]
10/7
35/2
Max. input current
Continuous
(3 x 200-240 V ) [A]
22.0
28.0
42.0
54.0
Intermittent
(3 x 200-240 V ) [A]
24.2
30.8
46.2
59.4
Max. pre-fuses
1)
[A]
63
63
63
80
Environment
Estimated power loss
at rated max. load [W]
4)
269
310
447
602
Weight enclosure IP20 [kg]
Weight enclosure IP21 [kg]
23
23
23
27
Weight enclosure IP55 [kg]
23
23
23
27
Weight enclosure IP 66 [kg]
23
23
23
27
Efficiency
4)
0.96
0.96
0.96
0.96
3. VLT HVAC Selection
VLT
®
HVAC Drive Design Guide
50
MG.11.B2.02 - VLT
®
is a registered Danfoss trademark
3
Содержание VLT series
Страница 78: ...4 How to Order VLT HVAC Drive Design Guide 78 MG 11 B2 02 VLT is a registered Danfoss trademark 4...
Страница 120: ...7 RS 485 Installation and Set up VLT HVAC Drive Design Guide 120 MG 11 B2 02 VLT is a registered Danfoss trademark 7...
Страница 152: ...8 Troubleshooting VLT HVAC Drive Design Guide 152 MG 11 B2 02 VLT is a registered Danfoss trademark 8...