1.3.2 Relations
This manual relates to the following hardware:
•
VLT
®
PROFIBUS Converter option, type no.
130B1246
•
MCB 101 General I/O option, type no. 130B1125
(uncoated), 130B1212 (coated)
•
MCB 107 External 24 Volt DC Supply, type no.
130B1108 (uncoated), 130B1208 (coated)
•
PROFIBUS adaptor Sub-D9 connector, type no.
130B1112. for enclosure types A1, A2 & A3
•
PROFIBUS adaptor Sub-D9 connector, type no.
176F1742 for enclosure types D & E
1.3.3 Hardware
•
The VLT
®
PROFIBUS Converter MCA 114 supports
VLT
®
AutomationDrive FC 302 only.
•
There is no support for PROFIBUS FMS networks.
•
The FC 302 has fewer digital I/Os and analog
output signals than VLT
®
5000. The General I/O
Option MCB 101 must be mounted in FC 302 to
map these signals and utilise all I/Os.
VLT
®
5000
FC 302
Terminal
Function
Terminal
Function
16
Digital input
X30/2*
Digital input
17
Digital input
X3/3*
Digital input
18
Digital input
18
Digital input
19
Digital input
19
Digital input
27
Digital input
27
Digital input
29
Digital input
29
Digital input
32
Digital input
32
Digital input
33
Digital input
33
Digital input
20
GND Digital
input
20
GND Digital input
53
Analog input
voltage
53
Analog input voltage**
54
Analog input
voltage
X30/11***
Analog input voltage
60
Analog input
current
54
Analog input
current***
55
GND analog/
digital input
voltage
55
GND analog/digital
input voltage
42
Analog/digital
output
42
Analog output 0/4-20
mA
X30/6*
Digital output
X30/7*
Pulse output
39
GND analog/
digital output
39
GND analog /digital
output
04-05
Relay
04-06
Relay
VLT
®
5000
FC 302
Terminal
Function
Terminal
Function
01-03
Relay
01-03
Relay
68
RS-485-P
68
RS-485-P
69
RS-485-N
69
RS-485-N
61
GND RS-485
61
GND RS-485
12
24 V out
12
24 V out
13
24 V out
13
24 V out
50
10 V out
50
10 V out
Table 1.1 Terminal Mapping
* = General I/O option MCB 101
** = Switch “S201” must be OFF
*** = Switch “S202” must be ON
130B
T310.11
Illustration 1.1 Location of Switches S801, S201, and S202 (Left
to Right)
Introduction
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
4
MG34N202 - Rev. 2013-10-15
1
1