5.3 VLT
®
5000 Parameter Group 2
VLT 5000 series
FC 302 series
Parameter 200 Output Frequency Range/
Direction
4-10 Motor Speed
Direction
Options
[0] Only clockwise, 0 – 132 Hz
[0] Clockwise
[1] Both directions, 0 – 132 Hz
[2] Both directions
[2] Only clockwise, 0 – 1000 Hz [0] Clockwise
[3] Both directions, 0 – 1000 Hz [2] Both directions
[4] Only counter clockwise, 0 –
132 Hz
[1] Counter
clockwise
[5] Only counter clockwise, 0 –
1000 Hz
[1] Counter
clockwise
Table 5.52 Conversion of Parameter 200
VLT 5000 series
FC 302 series
Parameter 201 Output frequency
low limit
4-12 Motor Speed Low
Limit [Hz]
Range
0.0 – par. 202 F
max
0 – par. 414 F
max
[Hz]
Table 5.53 Conversion of Parameter 201
VLT 5000 series
FC 302 series
Parameter 202 Output frequency
high limit
4-14 Motor Speed High
Limit [Hz]
4-19 Max Output Frequency
Range
0.0 – 132/1000 Hz
0 – 1000 Hz
Table 5.54 Conversion of Parameter 202
VLT 5000 series
FC 302 series
Parameter 203 Reference/feedback area 3-00 Reference Range
Options
[0] Min – Max
[0] Min – Max
[1] - Max - +Max
[1] - Max - +Max
Table 5.55 Conversion of Parameter 203
VLT 5000 series
FC 302 series
Parameter
204 Minimum
reference
3-02 Minimum
Reference
Range
-100,000.000 – par.
205 Ref
max
-100,000.000 – par.
3-03 Ref
max
Table 5.56 Conversion of Parameter 204
VLT 5000 series
FC 302 series
Parameter 205 Maximum
reference
3-03 Maximum Reference
6-15 Terminal 53 High Ref./Feedb.
Value
6-25 Terminal 54 High Ref./Feedb.
Value
5-53 Term. 29 High Ref./Feedb.
Value
5-58 Term. 33 High Ref./Feedb.
Value
Range
Par. 204 Ref
min
–
100,000.000
Par. 3-02 Ref
min
– 100,000.000
Table 5.57 Conversion of Parameter 205
VLT 5000 series
FC 302 series
Parameter 206 Ramp Type
3-40 Ramp 1 Type
3-50 Ramp 2 Type
3-82 Quick Stop Ramp Type
Options
[0] Linear
Par. 3-40 = [0] Linear
Par. 3-50 = [0] Linear
Par. 3-82 = [0] Linear
[1] Sine shape (S1) Par. 3-40 = [2] S-ramp Const Time
Par. 3-45 = 1%
Par. 3-46 = 25%
Par. 3-47 = 1%
Par. 3-48 = 25%
Par. 3-50 = [2] S-ramp Const Time
Par. 3-55 = 1%
Par. 3-56 = 25%
Par. 3-57 = 1%
Par. 3-58 = 25%
Par. 3-82 = [2] S-ramp Const Time
Par. 3-83 = 1%
Par. 3-84 = 25%
[2] Sin2 Shape
(S2)
Par. 3-40 = [2] S-ramp Const Time
Par. 3-45 = 25%
Par. 3-46 = 25%
Par. 3-47 = 25%
Par. 3-48 = 25%
Par. 3-50 = [2] S-ramp Const Time
Par. 3-55 = 25%
Par. 3-56 = 25%
Par. 3-57 = 25%
Par. 3-58 = 25%
Par. 3-82 = [2] S-ramp Const Time
Par. 3-83 = 25%
Par. 3-84 = 25%
Table 5.58 Conversion of Parameter 206
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
18