![Danfoss VLT series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/danfoss/vlt-series/vlt-series_operating-instructions-manual_3423181018.webp)
VLT 5000 series
FC 302 series
Parameter 114 Load compensation at
high speed
1-61 High Speed Load
Compensation
Range
0 – 300%
0 – 300%
Table 5.33 Conversion of Parameter 114
VLT 5000 series
FC 302 series
Parameter 115 Slip Compensation
1-62 Slip Compensation
Range
-500 - 500%
-500 - 500%
Table 5.34 Conversion of Parameter 115
VLT 5000 series
FC 302 series
Parameter 116 Slip Compensation
Time constant
1-63 Slip Compensation
Time Constant
Range
0.05 – 1.00 s
0.05 – 5.00 s
Table 5.35 Conversion of Parameter 116
VLT 5000 series
FC 302 series
Parameter 117 Resonance dampening 1-64 Resonance Damping
Range
0 - 500%
0 - 500%
Table 5.36 Conversion of Parameter 117
VLT 5000 series
FC 302 series
Parameter 118 Resonance
dampening time
constant
1-65 Resonance Damping
Time Constant
Range
5 – 50 ms
5 – 50 ms
Table 5.37 Conversion of Parameter 118
VLT 5000 series
FC 302 series
Parameter
119 High starting torque
Not converted
Table 5.38 Conversion of Parameters 119
VLT 5000 series
FC 302 series
Parameter
120 Start delay
1-71 Start Delay
Option
0.0 – 10.0 s
0.0 – 10.0 s
Table 5.39 Conversion of Parameter 120
VLT 5000 series
FC 302 series
Parameter 121 Start function
1-72 Start Function
Options
[0] DC hold in start delay
time
[0] DC hold/delay time
[1] DC brake in start delay
time
[1] DC Brake/delay
time
[2] Coasting in start delay
time
[2] Coast/delay time
[3] Start frequency/voltage
clockwise
[3] Start speed cw
[4] Start frequency/voltage
in reference direction
[4] Horizontal
operation
[5] VVC
plus
clockwise
[5] VVC
plus
/Flux
clockwise
Table 5.40 Conversion of Parameter 121
VLT 5000 series
FC 302 series
Parameter
122 Function at stop
1-80 Function at Stop
Options
[0] Coasting
[0] Coast
[1] DC hold
[1] DC hold
[2] Motor check
[2] Motor check
[3] Pre-magnetizing
[3] Pre-magnetizing
Table 5.41 Conversion of Parameter 122
VLT 5000 series
FC 302 series
Parameter 123 Min frequency for
function at stop
1-82 Min Speed for
Function at Stop [Hz]
Range
0.0 – 10.0 Hz
0.0 – 20.0 Hz
Table 5.42 Conversion of Parameter 123
VLT 5000 series
FC 302 series
Parameter 124 DC holding current 2-00 DC Hold Current
Range
0 - 100%
0 - 160% (motor depending)
Table 5.43 Conversion of Parameter 124
VLT 5000 series
FC 302 series
Parameter 125 DC braking current
2-01 DC Brake Current
Range
0 - 100%
0 – 160% P.U depending
Table 5.44 Conversion of Parameter 125
VLT 5000 series
FC 302 series
Parameter
126 DC braking time
2-02 DC Braking Time
Range
0.0 – 60.0 s
0.0 – 60.0 s
Table 5.45 Conversion of Parameter 126
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
16
MG34N202 - Rev. 2013-10-15
5
5