5.10 VLT
®
5000 Parameter Group 9
VLT 5000 series
FC 302 series
Parameter
900 Write PPO type 1
Not converted
Table 5.278 Conversion of Parameter 900
VLT 5000 series
FC 302 series
Parameter
901 Write PPO type 2
Not converted
Table 5.279 Conversion of Parameter 901
VLT 5000 series
FC 302 series
Parameter
902 Write PPO type 3
Not converted
Table 5.280 Conversion of Parameter 902
VLT 5000 series
FC 302 series
Parameter
903 Write PPO type 4
Not converted
Table 5.281 Conversion of Parameter 903
VLT 5000 series
FC 302 series
Parameter
904 PPO type select for DP
Not converted
Table 5.282 Conversion of Parameter 904
VLT 5000 series
FC 302 series
Parameter
907 Read PPO type 1
Not converted
Table 5.283 Conversion of Parameter 907
VLT 5000 series
FC 302 series
Parameter
908 Read PPO type 2
Not converted
Table 5.284 Conversion of Parameter 908
VLT 5000 series
FC 302 series
Parameter
909 Read PPO type 3
Not converted
Table 5.285 Conversion of Parameter 909
VLT 5000 series
FC 302 series
Parameter
910 Read PPO type 4
Not converted
Table 5.286 Conversion of Parameter 910
VLT 5000 series
FC 302 series
Parameter
911 PPO type for FMS read
Not converted
Table 5.287 Conversion of Parameter 911
VLT 5000 series
FC 302 series
Parameter
913 Broadcast index
Not converted
Table 5.288 Conversion of Parameter 913
VLT 5000 series
FC 302 series
Parameter
914 Broadcast off-set
Not converted
Table 5.289 Conversion of Parameter 914
VLT 5000 series
FC 302 series
Parameter 915 PCD config write
9-15 PCD Write Config-
uration
Options
[0] None
[0] None
[204] Minimum Reference
[302] Minimum
Reference
[205] Maximum Reference
[203] Maximum
Reference
[219] Catch up/slow Down
Value
[312] Catch up/slow
Down Value
[207] Ramp 1 Ramp up
Time
[341] Ramp 1 Ramp up
Time
[208] Ramp 1 Ramp Down
Time
[342] Ramp 1 Ramp
Down Time
[209] Ramp 2 Ramp up
Time
[351] Ramp 2 Ramp up
Time
[210] Ramp 2 Ramp down
Time
[352] Ramp 2 Ramp
down Time
[211] Jog Ramp Time
[380] Jog Ramp Time
[212] Quick Stop Ramp
Time
[381] Quick Stop Ramp
Time
[201] Motor Low Limit [Hz] [412] Motor Speed Low
Limit [Hz]
[202] Motor High Limit [Hz] [414] Motor Speed High
Limit [Hz]
[221] Torque Limit Motor
Mode
[416] Torque Limit
Motor Mode
[222] Torque Limit
Generator Mode
[417] Torque Limit
Generator Mode
[509] Bus Jog 1 Speed
[890] Bus Jog 1 Speed
[510] Bus Jog 2 Speed
[891] Bus Jog 2 Speed
Comments VLT
®
5000 supports more write signals. If a not-
supported signal is written then the corresponding
signal is set to
[0] None.
Table 5.290 Conversion of Parameter 915
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
40
MG34N202 - Rev. 2013-10-15
5