manualshive.com logo in svg
background image

5.7  VLT

®

 5000 Parameter Group 6

 

VLT 5000 series

FC 302 series

Parameter

600 Operating hours

15-00 Operating hours

Table 5.223 Conversion of Parameter 600

 

VLT 5000 series

FC 302 series

Parameter

601 Hours run

15-01 Running Hours

Table 5.224 Conversion of Parameter 601

 

VLT 5000 series

FC 302 series

Parameter

602 kWh counter

15-02 kWh Counter

Table 5.225 Conversion of Parameter 602

 

VLT 5000 series

FC 302 series

Parameter

603 Numbers of power up

15-03 Power Up's

Table 5.226 Conversion of Parameter 603

 

VLT 5000 series

FC 302 series

Parameter 604 Numbers of over temp.

15-04 Over Temp's

Table 5.227 Conversion of Parameter 604

 

VLT 5000 series

FC 302 series

Parameter 605 Numbers of over voltage

15-05 Over Volt's

Table 5.228 Conversion of Parameter 605

 

VLT 5000 series

FC 302 series

Parameter

606 Data log: Digital input

Not converted

Table 5.229 Conversion of Parameter 606

 

VLT 5000 series

FC 302 series

Parameter

607 Data log: Bus commands

Not converted

Table 5.230 Conversion of Parameter 607

 

VLT 5000 series

FC 302 series

Parameter

608 Data log: Status word

Not converted

Table 5.231 Conversion of Parameter 608

 

VLT 5000 series

FC 302 series

Parameter

609 Data log: Reference

Not converted

Table 5.232 Conversion of Parameter 609

 

VLT 5000 series

FC 302 series

Parameter

610 Data log: Feedback

Not converted

Table 5.233 Conversion of Parameter 610

 

VLT 5000 series

FC 302 series

Parameter

611 Data log: Motor frequency

Not converted

Table 5.234 Conversion of Parameter 611

 

VLT 5000 series

FC 302 series

Parameter

612 Data log: Motor voltage

Not converted

Table 5.235 Conversion of Parameter 612

 

VLT 5000 series

FC 302 series

Parameter

613 Data log: Motor current

Not converted

Table 5.236 Conversion of Parameter 613

 

VLT 5000 series

FC 302 series

Parameter

614 Data log: DC link voltage

Not converted

Table 5.237 Conversion of Parameter 614

 

VLT 5000 series

FC 302 series

Parameter 615 Fault log: Error code 15-30 Fault Log: Error Code

Table 5.238 Conversion of Parameter 615

 

VLT 5000 series

FC 302 series

Parameter

616 Fault log: Time

15-32 Fault Log: Time

Table 5.239 Conversion of Parameter 616

 

VLT 5000 series

FC 302 series

Parameter

617 Fault log: Value

15-31 Fault Log: Value

Table 5.240 Conversion of Parameter 617

 

VLT 5000 series

FC 302 series

Parameter 618 Reset of kWh counter 15-06 Reset kWh Counter
Options

[0] No reset

[0] Do not reset

[1] Reset

[1] Reset counter

Table 5.241 Conversion of Parameter 618

 

VLT 5000 series

FC 302 series

Parameter 619 Reset of Hours

run

15-07 Reset Running Hours
Counter

Options

[0] No reset

[0] Do not reset

[1] Reset

[1] Reset counter

Table 5.242 Conversion of Parameter 619

Parameter Mapping Lists

VLT

®

 AutomationDrive FC 302 PROFIBUS Converter Operating Instructions

36

MG34N202 - Rev. 2013-10-15

5

5

Содержание VLT series

Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT PROFIBUS Converter MCA 114 VLT AutomationDrive FC 302 VLT 5000 www danfoss com drives...

Страница 2: ......

Страница 3: ...ardware Switches 9 4 1 2 Setting the PROFIBUS Address via 9 18 Node Address 9 4 1 3 Commissioning 10 4 2 LED Behaviour 10 4 3 Initialisation 11 5 Parameter Mapping Lists 12 5 1 VLT 5000 Parameter Grou...

Страница 4: ...Index 44 Contents VLT AutomationDrive FC 302 PROFIBUS Converter Operating Instructions 2 MG34N202 Rev 2013 10 15...

Страница 5: ...VLT 5000 is automatically linked to the corresponding ramp up time parameter in VLT Automa tionDrive FC 302 NOTICE Some parameters in the VLT 5000 are not supported in the FC 302 and some FC 302 param...

Страница 6: ...ital input 27 Digital input 27 Digital input 29 Digital input 29 Digital input 32 Digital input 32 Digital input 33 Digital input 33 Digital input 20 GND Digital input 20 GND Digital input 53 Analog i...

Страница 7: ...hanges made with running motor ensure that FC 302 setups are linked This is done in 0 12 This Set up Linked to 1 4 Abbreviations AOC Application oriented control CTW Control word EMC Electromagnetic C...

Страница 8: ...e mains supply has been disconnected and that the necessary time has passed before removing motor and mains plugs see Discharge Time Table 7 The frequency converter has more voltage inputs than L1 L2...

Страница 9: ...s connector Unlike the VLT 5000 the FC 302 Profibus connectors are colour coded to avoid swapping the bus wires Illustration 3 1 Connecting Bus Wires to VLT PROFIBUS Converter MCA 114 Profibus B 62 Rx...

Страница 10: ...adapter plates are available Ordering number Style Height mm Width mm Type 130B0183 Bookstyle IP20 395 90 5001 5003 200 240 V 5001 5005 380 500 V 130B0184 Bookstyle IP20 395 130 5004 5006 200 240 V 5...

Страница 11: ...Node Address Using the hardware switches select an address range from 0 to 125 factory setting 127 according to Illustration 4 1 ON 1 OFF 0 MCA 114 Profibus Converter MS NS Option A 130B1246 NS MS ON...

Страница 12: ...erising Green Long green flash Baud rate found waiting for parameters from the master Red Long red flash Wrong parameters from the master Wait Configuration Green Short green flash Parameters from mas...

Страница 13: ...arning Feedback High 4000000 6 10 Terminal 53 Low Voltage 0 00 Volt 6 20 Terminal 54 Low Voltage 0 00 Volt 6 22 Terminal 54 Low Current 0 00 Volt 5 51 Term 29 High Frequency 5000 Hz 5 56 Term 33 High...

Страница 14: ...up 4 4 Setup 4 5 Active Setup 9 Active Setup Table 5 5 Conversion of Parameter 005 VLT 5000 series FC 302 series Parameter 006 Setup Copy 0 51 Set up Copy Options 0 No Copy 0 No Copy 1 1 2 2 3 3 4 4 T...

Страница 15: ...0 series FC 302 series Parameter 013 Local Ctrl config Not converted Table 5 11 Conversion of Parameter 013 VLT 5000 series FC 302 series Parameter 014 Local Stop key 0 41 Off Key on LCP Options 0 Dis...

Страница 16: ...9 Conversion of Parameter 100 VLT 5000 series FC 302 series Parameter 101 Torque charac teristic 1 03 Torque Characteristics 1 04 Overload Mode 14 40 VT Level Options 1 High constant torque Par 1 03 0...

Страница 17: ...00 Volt 50 1000 V Table 5 23 Conversion of Parameter 103 VLT 5000 series FC 302 series Parameter 104 Motor frequency 1 23 Motor Frequency Range 20 1000 Hz 20 1000 Hz Table 5 24 Conversion of Parameter...

Страница 18: ...C hold in start delay time 0 DC hold delay time 1 DC brake in start delay time 1 DC Brake delay time 2 Coasting in start delay time 2 Coast delay time 3 Start frequency voltage clockwise 3 Start speed...

Страница 19: ...3 9 ETR warning 4 9 ETR warning 4 10 ETR trip 4 10 ETR trip 4 Table 5 47 Conversion of Parameter 128 VLT 5000 series FC 302 series Parameter 129 External motor fan 1 91 Motor External Fan Options 0 N...

Страница 20: ...Minimum reference 3 02 Minimum Reference Range 100 000 000 par 205 Refmax 100 000 000 par 3 03 Refmax Table 5 56 Conversion of Parameter 204 VLT 5000 series FC 302 series Parameter 205 Maximum refere...

Страница 21: ...Range 0 05 3600 00 s 0 01 3600 00 s Table 5 64 Conversion of Parameter 211 VLT 5000 series FC 302 series Parameter 212 Quick stop ramp time 3 81 Quick Stop Ramp Time Range 0 05 3600 00 s 0 01 3600 00...

Страница 22: ...228 999 999 999 par 4 57 Table 5 79 Conversion of Parameter 227 VLT 5000 series FC 302 series Parameter 228 Warning High Feedback 4 57 Warning Feedback High Range par 227 100 000 000 Par 4 56 999 999...

Страница 23: ...down 10 Choice of setup msb 24 Setup select bit 1 11 Slow down 29 Slow down 12 Ramp 2 34 Ramp bit 0 13 Mains failure inverted Not supported 23 Pulse reference 32 Pulse input 24 Safety interlock Not su...

Страница 24: ...reset reference bit 0 7 Freeze reference 19 Freeze reference 8 Freeze output 20 Freeze output 9 Speed up 21 Speed up 10 Choice of Setup lsb 23 Setup select bit 0 11 Choice of Setup msb Speed up Not su...

Страница 25: ...oltage Range 0 10 0 Volt Par 6 10 10 00 Volt Table 5 97 Conversion of Parameter 310 VLT 5000 series FC 302 series Parameter 311 Terminal 54 Analogue Input Voltage 3 16 Reference Resource 2 7 00 Speed...

Страница 26: ...s FC 302 series Parameter 318 Function after time out 6 01 Live Zero Timeout Function Options 0 Off 0 Off 1 Freeze output frequency 1 Freeze output frequency 2 Stop 2 Stop 3 Jogging 3 Jog 4 Max Speed...

Страница 27: ...ersion of Parameters 319 to 321 VLT 5000 series FC 302 series Parameter 319 Terminal 42 Output Digital Par 5 32 DO X30 7 MCB 101 Analogue values Par 6 50 AO 42 Pulse Par 5 66 DO X30 6 Parameter 321 Te...

Страница 28: ...000 57 0 P nom 0 20 mA Par 6 50 106 Power related to norm 0 20 mA 58 0 P nom 4 20 mA Par 6 50 136 Power related to norm 4 20 mA 59 0 P nom 0 32000 p Par 5 66 106 Power related to norm 0 32000p Par 5 6...

Страница 29: ...ion Relay Range 22 Ready no thermal warning Par 5 40 12 Ready no thermal W 23 Ready remote control no thermal warning Par 5 40 23 Remote ready no TW 24 Ready mains voltage within range Par 5 40 24 Rea...

Страница 30: ...x speed 5 Max speed 5 Stop and trip 11 Stop and trip 7 Select setup 4 10 Select setup 4 Table 5 122 Conversion of Parameter 346 VLT 5000 series FC 302 series Parameter 357 Term 42 Output min scale 6 5...

Страница 31: ...2 series Parameter 405 Reset 14 20 Reset Mode Options 0 Manual reset 0 Off 1 Automatic reset x 1 1 Automatic reset x 1 2 Automatic reset x 2 2 Automatic reset x 2 3 Automatic reset x 3 3 Automatic res...

Страница 32: ...Parameter 413 Overmodulation function 14 03 Overmodulation function Options 0 Off 0 Off 1 On 1 On Table 5 141 Conversion of Parameter 413 VLT 5000 series FC 302 series Parameter 414 Minimum feedback N...

Страница 33: ...FC 302 series Parameter 421 Speed PID low pass filter 7 06 Speed PID Lowpass Filter Time Data range 5 0 200 0 ms 1 0 100 0 Table 5 150 Conversion of Parameter 421 VLT 5000 series FC 302 series Paramet...

Страница 34: ...e 5 164 Conversion of Parameter 437 VLT 5000 series FC 302 series Parameter 438 Process PID Anti windup 7 31 Process PID Anti Windup Options 0 Off 0 Off 1 On 1 On Table 5 165 Conversion of Parameter 4...

Страница 35: ...Voltage at Mains Fault Range 180 690 V 100 800 V Table 5 177 Conversion of Parameter 450 VLT 5000 series FC 302 series Parameter 453 Gear ratio speed close loop 7 07 Speed PID Feedback Gear Ratio Ran...

Страница 36: ...series FC 302 series Parameter 513 Bus time interval Not Converted Table 5 189 Conversion of Parameter 513 VLT 5000 series FC 302 series Parameter 514 Bus time interval function Not Converted Table 5...

Страница 37: ...ord Table 5 210 Conversion of Parameter 534 VLT 5000 series FC 302 series Parameter 535 Brake power 2 min 16 33 Brake Energy 2 min Table 5 211 Conversion of Parameter 535 VLT 5000 series FC 302 series...

Страница 38: ...s Parameter 610 Data log Feedback Not converted Table 5 233 Conversion of Parameter 610 VLT 5000 series FC 302 series Parameter 611 Data log Motor frequency Not converted Table 5 234 Conversion of Par...

Страница 39: ...24 VLT 5000 series FC 302 series Parameter 625 Name plate LCP ID no Not converted Table 5 248 Conversion of Parameter 625 VLT 5000 series FC 302 series Parameter 626 Name plate Data base ID Not conver...

Страница 40: ...s FC 302 series Parameter 706 PID Active bandwidth 32 64 PID Bandwidth Options 0 65000 0 1000 Table 5 261 Conversion of Parameter 706 VLT 5000 series FC 302 series Parameter 707 PID Velocity Feed forw...

Страница 41: ...Stop and trip 6 No com option control Par 802 to RS485 7 Select set up 4 10 Select set up 4 Table 5 273 Conversion of Parameter 804 VLT 5000 series FC 302 series Parameter 805 Function of control word...

Страница 42: ...er 911 VLT 5000 series FC 302 series Parameter 913 Broadcast index Not converted Table 5 288 Conversion of Parameter 913 VLT 5000 series FC 302 series Parameter 914 Broadcast off set Not converted Tab...

Страница 43: ...eter 917 VLT 5000 series FC 302 series Parameter 918 Station address 9 18 Node Address Range 0 125 0 125 Table 5 293 Conversion of Parameter 918 VLT 5000 series FC 302 series Parameter 927 Parameter e...

Страница 44: ...etups 2 Save edit setup 1 Store all setups 3 Save all setups 1 Store all setups Table 5 302 Conversion of Parameter 971 VLT 5000 series FC 302 series Parameter 980 981 982 990 Modified parameters Not...

Страница 45: ...no master has been detected the parameter displays No baud rate found Check 9 53 Profibus Warning Word Bit Warn Word Hex Description 0 0001 Connection with DP master is not OK 1 0002 Unused 2 0004 FD...

Страница 46: ...age 6 I Installation 7 L LEDs 10 Linked Set ups 5 Literature 3 M MCA 114 43 Mechanical Installation 8 N Node address 9 O Overview technical 3 P Parameter mapping list 12 Performance 5 Power size 3 T T...

Страница 47: ...Index VLT AutomationDrive FC 302 PROFIBUS Converter Operating Instructions MG34N202 Rev 2013 10 15 45...

Страница 48: ...www danfoss com drives MG34N202 130R0371 MG34N202 Rev 2013 10 15...

Отзывы: