Control characteristics:
Resolution of output frequency at 0–1000 Hz
: +/- 0.003 Hz
System response time (terminals 18, 19, 27, 29, 32, 33)
:
≤
2 ms
Speed control range (open-loop)
1:100 of synchronous speed
Speed accuracy (open-loop)
30–4000 rpm: Maximum error of
±
8 rpm
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:
Enclosure, frame size D and E
IP 21, IP 54 (hybrid)
Enclosure, frame size F
IP 21, IP 54 (hybrid)
Vibration test
0.7 g
Relative humidity
5–95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation
Aggressive environment (IEC 60068-2-43) H
2
S test
class kD
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature (at 60 AVM switching mode)
- with derating
max. 131°F [55
°
C]
1)
- with full output power, typical EFF2 motors
max. 122°F [50
°
C]
1)
- at full continuous FC output current
max. 113°F [45
°
C]
1)
1)
For more information on derating see the Design Guide, section on Special Conditions.
Minimum ambient temperature during full-scale operation
32°F [0
°
C]
Minimum ambient temperature at reduced performance
14°F [- 10
°
C]
Temperature during storage/transport
-13°–+149°/158°F [-25°–+65°/70°
°
C]
Maximum altitude above sea level without derating
3280 ft [1000 m]
Maximum altitude above sea level with derating
9842 ft [3000 m]
Derating for high altitude, see section on special conditions
EMC standards, Emission
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EMC standards, Immunity
EN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
See section on special conditions!
Control card performance:
Scan interval
: 5 ms
Control card, USB serial communication:
USB standard
1.1 (Full speed)
USB plug
USB type B “device” plug
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
The USB connection is not galvanically isolated from protection ground. Use only isolated laptop/PC as connection to the USB connector
on the adjustable frequency drive or an isolated USB cable/drive.
Protection and Features:
•
Electronic thermal motor protection against overload.
•
Temperature monitoring of the heatsink ensures that the adjustable frequency drive trips if the temperature reaches a predefined level. An
overload temperature cannot be reset until the temperature of the heatsink is below the values stated in the tables on the following pages
(guideline - these temperatures may vary for different power sizes, frame sizes, enclosure ratings, etc.).
•
The adjustable frequency drive is protected against short-circuits on motor terminals U, V, W.
•
If a line phase is missing, the adjustable frequency drive trips or issues a warning (depending on the load).
•
Monitoring of the intermediate circuit voltage ensures that the adjustable frequency drive trips if the intermediate circuit voltage is too low or
too high.
•
The adjustable frequency drive is protected against ground faults on motor terminals U, V, W.
8 General Specifications
VLT HVAC Low Harmonic Drive Instruction
Manual
8-4
MG.16.A1.22 - VLT
®
is a registered Danfoss trademark
8