6.4.5 FC Information 15-**
Par.
No. #
Parameter description
Default value
(SR = Size related)
4 set-up
FC 302
only
Change during
operation
Conver-
sion index
Type
15-0* Operating Data
15-00 Operating Hours
0 h
All set-ups
FALSE
74
Uint32
15-01 Running Hours
0 h
All set-ups
FALSE
74
Uint32
15-03 Power-ups
0 N/A
All set-ups
FALSE
0
Uint32
15-04 Overtemps
0 N/A
All set-ups
FALSE
0
Uint16
15-05 Overvolts
0 N/A
All set-ups
FALSE
0
Uint16
15-07 Reset Running Hours Counter
[0] Do not reset
All set-ups
TRUE
-
Uint8
15-1* Data Log Settings
15-10 Logging Source
0
2 set-ups
TRUE
-
Uint16
15-11 Logging Interval
ExpressionLimit
2 set-ups
TRUE
-3
TimD
15-12 Trigger Event
[0] False
1 set-up
TRUE
-
Uint8
15-13 Logging Mode
[0] Log always
2 set-ups
TRUE
-
Uint8
15-14 Samples Before Trigger
50 N/A
2 set-ups
TRUE
0
Uint8
15-2* Historic Log
15-20 Historic Log: Event
0 N/A
All set-ups
FALSE
0
Uint8
15-21 Historic Log: Value
0 N/A
All set-ups
FALSE
0
Uint32
15-22 Historic Log: Time
0 ms
All set-ups
FALSE
-3
Uint32
15-3* Fault Log
15-30 Fault Log: Error Code
0 N/A
All set-ups
FALSE
0
Uint16
15-31 Fault Log: Value
0 N/A
All set-ups
FALSE
0
Int16
15-32 Fault Log: Time
0 s
All set-ups
FALSE
0
Uint32
15-4* Unit Identification
15-40 FC Type
0 N/A
All set-ups
FALSE
0
VisStr[6]
15-41 Power Section
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-42 Voltage
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-43 Software Version
0 N/A
All set-ups
FALSE
0
VisStr[5]
15-44 Ordered Typecode String
0 N/A
All set-ups
FALSE
0
VisStr[40]
15-45 Actual Typecode String
0 N/A
All set-ups
FALSE
0
VisStr[40]
15-46 Unit Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-47 Power Card Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-48 LCP ID No
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-49 SW ID Control Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-50 SW ID Power Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-51 Unit Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[10]
15-53 Power Card Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[19]
15-6* Option Ident
15-60 Option Mounted
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-61 Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-62 Option Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-63 Option Serial No
0 N/A
All set-ups
FALSE
0
VisStr[18]
15-70 Option in Slot A
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-71 Slot A Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-72 Option in Slot B
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-73 Slot B Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-74 Option in Slot C0
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-75 Slot C0 Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-76 Option in Slot C1
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-77 Slot C1 Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-9* Parameter Info
15-92 Defined Parameters
0 N/A
All set-ups
FALSE
0
Uint16
15-93 Modified Parameters
0 N/A
All set-ups
FALSE
0
Uint16
15-98 Unit Identification
0 N/A
All set-ups
FALSE
0
VisStr[40]
15-99 Parameter Metadata
0 N/A
All set-ups
FALSE
0
Uint16