6.4.6 Data Readouts 16-**
Par.
No. #
Parameter description
Default value
(SR = Size related)
4 set-up
FC 302
only
Change dur-
ing opera-
tion
Conver-
sion index
Type
16-0* General Status
16-00 Control Word
0 N/A
All set-ups
FALSE
0
V2
16-03 Status Word
0 N/A
All set-ups
FALSE
0
V2
16-3* AF Status
16-30 DC Link Voltage
0 V
All set-ups
FALSE
0
Uint16
16-34 Heatsink Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-35 Inverter Thermal
0 %
All set-ups
FALSE
0
Uint8
16-36 Inv. Nom. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-37 Inv. Max. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-40 Logging Buffer Full
[0] No
All set-ups
TRUE
-
Uint8
16-49 Current Fault Source
0 N/A
All set-ups
TRUE
0
Uint8
16-6* Inputs & Outputs
16-60 Digital Input
0 N/A
All set-ups
FALSE
0
Uint16
16-66 Digital Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-71 Relay Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-84 Comm. Option STW
0 N/A
All set-ups
FALSE
0
V2
16-85 FC Port CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-9* Diagnosis Readouts
16-90 Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
16-91 Alarm Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-92 Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
16-93 Warning Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-94 Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
6.4.7 AF Settings 300-**
NOTE!
Except for par. 300-10, it is not recommended to change the settings in this par. group for the Low Harmonic Drive.
Par.
No. #
Parameter description
Default value
(SR = Size related)
4 set-up
FC 302
only
Change
during op-
eration
Conver-
sion index
Type
300-0* General Settings
300-00 Harmonic Cancellation Mode
[0] Overall
All set-ups
TRUE
-
Uint8
300-01 Compensation Priority
[0] Harmonics
All set-ups
TRUE
-
Uint8
300-1* Network Settings
300-10 Active Filter Nominal Voltage
ExpressionLimit
2 set-ups
FALSE
0
Uint32
300-2* CT Settings
300-20 CT Primary Rating
ExpressionLimit
2 set-ups
FALSE
0
Uint32
300-21 CT Secondary Rating
[1] 5A
2 set-ups
FALSE
-
Uint8
300-22 CT Nominal Voltage
342 V
2 set-ups
FALSE
0
Uint32
300-24 CT Sequence
[0] L1, L2, L3
2 set-ups
FALSE
-
Uint8
300-25 CT Polarity
[0] Normal
2 set-ups
FALSE
-
Uint8
300-26 CT Placement
[1] Load Current
2 set-ups
FALSE
-
Uint8
300-29 Start Auto CT Detection
[0] Off
All set-ups
FALSE
-
Uint8
300-3* Compensation
300-30 Compensation Points
0.0 A
All set-ups
TRUE
-1
Uint32
300-35 Cos-phi Reference
0.500 N/A
All set-ups
TRUE
-3
Uint16
VLT HVAC Low Harmonic Drive Instruction
Manual
6 How to Program the Low Harmonic Drive
MG.16.A1.22 - VLT
®
is a registered Danfoss trademark
6-67