6.3.8 6-** Analog In / Out
Par.
No. #
Parameter description
Default value
(SR = Size related)
4 set-up
Change dur-
ing operation
Conver-
sion index
Type
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
10 s
All set-ups
TRUE
0
Uint8
6-01
Live Zero Timeout Function
[0] Off
All set-ups
TRUE
-
Uint8
6-02
Fire Mode Live Zero Timeout Function
[0] Off
All set-ups
TRUE
-
Uint8
6-1* Analog Input 53
6-10
Terminal 53 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-11
Terminal 53 High Voltage
10.00 V
All set-ups
TRUE
-2
Int16
6-12
Terminal 53 Low Current
4.00 mA
All set-ups
TRUE
-5
Int16
6-13
Terminal 53 High Current
20.00 mA
All set-ups
TRUE
-5
Int16
6-14
Terminal 53 Low Ref./Feedb. Value
0.000 N/A
All set-ups
TRUE
-3
Int32
6-15
Terminal 53 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-16
Terminal 53 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-17
Terminal 53 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
6-2* Analog Input 54
6-20
Terminal 54 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-21
Terminal 54 High Voltage
10.00 V
All set-ups
TRUE
-2
Int16
6-22
Terminal 54 Low Current
4.00 mA
All set-ups
TRUE
-5
Int16
6-23
Terminal 54 High Current
20.00 mA
All set-ups
TRUE
-5
Int16
6-24
Terminal 54 Low Ref./Feedb. Value
0.000 N/A
All set-ups
TRUE
-3
Int32
6-25
Terminal 54 High Ref./Feedb. Value
100.000 N/A
All set-ups
TRUE
-3
Int32
6-26
Terminal 54 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-27
Terminal 54 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
6-3* Analog Input X30/11
6-30
Terminal X30/11 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-31
Terminal X30/11 High Voltage
10.00 V
All set-ups
TRUE
-2
Int16
6-34
Term. X30/11 Low Ref./Feedb. Value
0.000 N/A
All set-ups
TRUE
-3
Int32
6-35
Term. X30/11 High Ref./Feedb. Value
100.000 N/A
All set-ups
TRUE
-3
Int32
6-36
Term. X30/11 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-37
Term. X30/11 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
6-4* Analog Input X30/12
6-40
Terminal X30/12 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-41
Terminal X30/12 High Voltage
10.00 V
All set-ups
TRUE
-2
Int16
6-44
Term. X30/12 Low Ref./Feedb. Value
0.000 N/A
All set-ups
TRUE
-3
Int32
6-45
Term. X30/12 High Ref./Feedb. Value
100.000 N/A
All set-ups
TRUE
-3
Int32
6-46
Term. X30/12 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-47
Term. X30/12 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
6-5* Analog Output 42
6-50
Terminal 42 Output
null
All set-ups
TRUE
-
Uint8
6-51
Terminal 42 Output Min Scale
0.00 %
All set-ups
TRUE
-2
Int16
6-52
Terminal 42 Output Max Scale
100.00 %
All set-ups
TRUE
-2
Int16
6-53
Terminal 42 Output Bus Control
0.00 %
All set-ups
TRUE
-2
N2
6-54
Terminal 42 Output Timeout Preset
0.00 %
1 set-up
TRUE
-2
Uint16
6-6* Analog Output X30/8
6-60
Terminal X30/8 Output
[0] No operation
All set-ups
TRUE
-
Uint8
6-61
Terminal X30/8 Min. Scale
0.00 %
All set-ups
TRUE
-2
Int16
6-62
Terminal X30/8 Max. Scale
100.00 %
All set-ups
TRUE
-2
Int16
6-63
Terminal X30/8 Output Bus Control
0.00 %
All set-ups
TRUE
-2
N2
6-64
Terminal X30/8 Output Timeout Preset
0.00 %
1 set-up
TRUE
-2
Uint16