9-16 PCD Read Configuration
Select the parameters to be assigned to PCD 3–10 of the
telegrams. The number of available PCDs depends on the
telegram type. Values in PCD 3–10 contain the actual data values
of the selected parameters.
Option:
Function:
[1695]
Ext. Status Word 2
[1697]
Alarm Word 3
[1850]
Sensorless Readout [unit]
9-18 Node Address
Range:
Function:
126
*
[ 0 -
126 ]
Enter the station address in this parameter or,
alternatively, in the hardware switch. To adjust the
station address in
,
set the hardware switch to 126 or 127 (that is all
switches set to
on
). Otherwise, this parameter
shows the actual setting of the switch.
9-19 Drive Unit System Number
Range:
Function:
1038
*
[0 - 65535 ]
Manufacturer-specific system ID.
9-22 Telegram Selection
Option:
Function:
[1]
Standard telegram 1 Select a standard PROFIBUS
telegram configuration for the
frequency converter as an
alternative to the freely config-
urable telegrams in
parameter 9-15 PCD Write Configu-
ration
and
parameter 9-16 PCD Read
Configuration
.
[100]
*
None
[101]
PPO 1
[102]
PPO 2
[103]
PPO 3
[104]
PPO 4
[105]
PPO 5
[106]
PPO 6
[107]
PPO 7
[108]
PPO 8
[200]
Custom telegram 1
9-23 Parameters for Signals
Option:
Function:
[0]
*
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
9-23 Parameters for Signals
Option:
Function:
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[412]
Motor Speed Low Limit [Hz]
[414]
Motor Speed High Limit [Hz]
[553]
Term. 29 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[615]
Terminal 53 High Ref./Feedb. Value
[625]
Terminal 54 High Ref./Feedb. Value
[696]
Terminal 42 Output Bus Control
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[894]
Bus Feedback 1
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1618]
Motor Thermal
[1622]
Torque [%]
[1626]
Power Filtered [kW]
[1627]
Power Filtered [hp]
[1630]
DC Link Voltage
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback[Unit]
[1660]
Digital Input
[1661]
Terminal 53 Setting
[1662]
Analog Input AI53
[1663]
Terminal 54 Setting
[1664]
Analog Input AI54
[1665]
Analog Output AO42 [mA]
[1666]
Digital Output
[1667]
Pulse Input #29 [Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1679]
Analog Output AO45
[1680]
Fieldbus CTW 1
Parameters
VLT
®
DriveMotor FCP 106/FCM 106
78