2 Programming
2.1 Programming with MCT 10 Set-up
Software
The frequency converter can be programmed from the LCP,
or from a PC via the RS485 COM port by installing the MCT
10 Set-up Software. Refer to
for more details about the software.
2.2 Graphical Local Control Panel (GLCP)
The GLCP is divided into 4 functional sections.
A. Alphanumeric display.
B. Menu selection.
C. Navigation keys and indicator lights (LEDs).
D. Operation keys and indicator lights (LEDs).
130BD512.10
Auto
on
Reset
Hand
on
Off
Status
Quick
Menu
Main
Menu
Alarm
Log
Back
Canc
el
In
fo
OK
Status
1(1)
0.00 kW
Off Remote Stop
0.0Hz
On
Alarm
Warn.
A
0.00 A
0.0 %
B
C
D
2605 kWh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Illustration 2.1 Graphical Local Control Panel (GLCP)
A. Display area
The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or a
24 V DC external supply.
The information shown on the GLCP can be customized for
user application. Select options in the Quick Menu
Q3-13
Display settings
.
Call-
out
Display
Parameter
number
Default setting
1
1.1
0-20
Reference %
2
1.2
0-21
Motor current
3
1.3
0-22
Power [kW]
4
2
0-23
Frequency
5
3
0-24
kWh counter
Table 2.1 Legend to
B. Display menu key
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Callout Key
Function
6
Status
Shows operational information.
7
Quick Menu
Allows access to programming
parameters for initial set-up
instructions and many detailed
application instructions.
8
Main Menu
Allows access to all programming
parameters.
9
Alarm Log
Shows a list of current warnings,
the last 10 alarms, and the
maintenance log.
Table 2.2 Legend to
C. Navigation keys and indicator lights (LEDs)
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local operation. There are also 3
frequency converter status indicator lights in this area.
Callout
Key
Function
10
Back
Reverts to the previous step or list in
the menu structure.
11
Cancel
Cancels the last change or command
as long as the display mode has not
changed.
12
Info
Press for a definition of the function
shown.
13
Navigation keys Press to move between items in the
menu.
14
OK
Press to access parameter groups or
to enable a selection.
Table 2.3 Legend to
Programming
VLT
®
DriveMotor FCP 106/FCM 106
8
Danfoss A/S © 11/2015 All rights reserved.
MG03N202
2
2