[26]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
Manually Adding a New Profile
This is possible to do using only the keys on the control itself but this requires multiple steps that
be done correctly. Do not try this unless you are a distributor with training from Dairy Tech
personnel.
Control Configuration -
Don’t reset to factory defaults!
In this menu, we set the configurations for the control which help determine the PID temperature
control process. This information is provided as a reference but should never be required unless you
have contacted Dairy Tech service technicians about a problem and they ask you to reference these
parameters for troubleshooting purposes. Do not adjust any of these parameters as this will change the
function of the machine and void your warranty on the controller.
From the operational mode when the machine is first turned on hold the RETURN button and press the
UP ARROW one time. Then use the DOWN ARROW to scroll to ‘configuration menu’. Press the
RETURN button and enter the unlock code which is 10 by scrolling with the UP ARROW, the
RETURN.
Scroll down and choose ‘control configuration’ from the menu and press RETURN.
You are now in the menu and can move back and forth using the RETURN or BACK ARROW keys,
and the UP and DOWN keys to make adjustments. Here are the settings
Control enable/disable
control enabled
Select auto/manual control
automatic control only
Control type
single
Primary control action
Reverse
Control status
(Do nothing … it will show ambient and setpt)
Primary Power
0.0%
Primary Proportional Band
0.5%
Integral Time
15:00
Derivative Time
3:55
Manual Reset Bias
25%
Primary Cycle Time
20.0 sec
Primary Power lower limit
0.0%
Primary Power Upper Limit
100.0%
Sensor Break
OFF
Setpoint Selection Method
Local Setpt 1 Only
Setpoint Lower Limit
0 F
(also 0 when in Celsius)
Setpoint Upper Limit
300 F (set at 100 when in Celsius)
Ramp in Operator Mode
NO
Setpoint Ramp Rate
OFF
Local Setpoint 1 Value
7
Содержание Platinum Series
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...