[11]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
WATER DRAIN: This 4’ black hose is connected internally
and takes cold water out of the unit once it has absorbed heat
during the cooling cycle. It should be directed to a drain,
cistern, stock tank or other collection system.
Do not connect
the hose to another hose or to any system that can create
back-pressure. This will cause damage to the cooling jacket
and void the warranty.
If you wish to salvage the waste water,
direct the drain line to a 5 gallon bucket and place an
inexpensive sump pump in that bucket to send water where it
needs to go. This prevents any back pressure to the unit.
It is important to keep water turned on anytime the pasteurizer
is in operation to prevent damage to the heating elements.
Electrical Requirements
The standard electrical cord emerging from the back of the
machine should be plugged directly into a 240vac grounded
receptacle on a 30amp breaker for DT10G Models, a 30amp
breaker for DT30G Models and a 50amp breaker for DT60G
Models. Take special note of the electrical label on the back of
the machine to be sure. Failure to meet these requirements will
void the warranty and could result in serious damage to the
unit, bodily injury or death. The receptacle should be fitted
with a water resistant cover for added protection. ALL
CONNECTIONS SHOULD BE PERFORMED BY AN
ELECTRICIAN OR OTHER TRAINED PERSONNEL.
The receptacle should be sharing minimal usage with
other equipment to avoid unexpected outages and
tripping of the breaker. If the power is lost, but
returns within 1 hour, the cycle will resume
automatically in most instances.
DT10G units at full power are rated at 15 amps at
230vac. Do not install on circuit breakers greater than
30 amps.
DT30G units at full power are rated at 18 amps at
230vac. Do not install on a circuit breaker greater
than 30 amps.
DT60G units at full power are rated at 35 amps at
230vac. Do not install on circuit breaker greater than
50 amps.
European Installations must be done with a switch or
circuit breaker disconnect within reach of the
equipment for power down, which should be labeled
as such.
DO NOT use an extension cord to operate the unit
other than the one provided.
Check your electrical system to make certain it is
properly grounded to avoid the possibility of
electrical shock.
See next image for location of the power cord if one
was supplied with your equipment.
International Installations for 10, 30 &
60G
International installations are equipped with a built-in step-
down transformer when necessary. For machines designed
prior to March 2012, there may be components that require a
120vac supply for control function.
Some International models are not supplied with power cords
per local electrical ordinances. Follow the labels attached to the
back of the machine for specific wiring instructions in these
instances.
Содержание Platinum Series
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...