[14]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
Using the Pasteurizer
Initial cleaning of the milk pot may be necessary to remove oil
residues from the manufacturing process. Next, simply add
milk or colostrum and replace the lid. You are now ready to
choose one of the operational options listed below.
Try to avoid excessive splashing or spilling of the
product as it is being poured into the unit. Clean spills with a
damp cloth as quickly as possible.
Do not overfill the pot as the milk will splash out
from under the lid while being stirred.
Running the Cycles
Don’t reset to factory defaults!
Power the unit on by toggling the red rocker switch or
push in the red button switch
; the display should run
through some diagnostics, display a red Dairy Tech Inc
logo and then be ready for use once back to a green color.
The Dairy Tech ProVu control system is designed with
multiple menus to choose from. Custom menus are
available if there are specific needs of a dairy. Use the
return arrow key to the right (
)
to choose the
operational mode screen with the options to Run, Abort,
etc.
Using the down arrow
, select Run Profile and then
press the return arrow key
.
Using the down arrow
, select a profile that you wish to
run then press the return arrow key
.
FOR THE
FIRST USE OF THE MACHINE, SELECT THE
COLOSTRUM COOL ONLY PROFILE. FOLLOW
OTHER INSTRUCTIONS ON PREVIOUS PAGE.
You will be asked if you are sure. Select YES and then
press the return arrow
key once again. The cycle
should automatically start at this time and no further
action is required until the cycle is finished.
If you need to stop a cycle, turn off the toggle switch or
disconnect the power in an emergency situation;
otherwise, repeat the steps above and select ABORT the
profile, then YES to confirm the action.
The following menu options are available on all DT10G,
DT30G and DT60G models.
Colostrum Normal Profile
Colostrum Heat Only
Colostrum Reheat Profile
Colostrum Cool Only
Milk 145
Milk 161
Colostrum Normal is chosen for pasteurizing to 140F for
60 minutes with cool down to 90F.
Colostrum Heat Only is used to pasteurize to 140 for 60
minutes without cooling.
Colostrum Reheat is used to warm milk or colostrum
back to feeding temperatures if it has been cooled after
pasteurization.
Colostrum Cool is to cool down milk or colostrum that
was previously pasteurized, or to fill the tank with water
on initial use.
Milk 145 is used to pasteurize milk only batches at 145F
for 30 minutes then cooling back to 90F
Milk 161 is used to pasteurizer milk only to 161F for 30
seconds and then cooling back to 90F
Содержание Platinum Series
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...