[28]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
To change a Profile -
Don’t reset to factory defaults!
From the operational mode when the machine is first turned on hold the RETURN button and press the
UP ARROW one time to main menu. Then use the DOWN ARROW to scroll to ‘profile setup’. Press
the RETURN button and enter the unlock code which is 10 by scrolling with the UP ARROW, the
RETURN.
Scroll down to Edit a Profile Segment, then RETURN, then select the profile to edit and press
RETURN again. Now you will see the list of segments that make up the profile. For a ‘colostrum
normal’ profile it will look like this:
1.
Step
2.
Ramp Rate
3.
Dwell
4.
Ramp Time
5.
End
Select a segment by highlighting it then RETURN. Here is a list of how the settings should appear in
each of those segments (Other profiles will have different segments and different settings depending on
their purpose) This example shows the settings for
COLOSTRUM NORMAL
1. Step:
Segment type
step
Target setpoint
139.0 F
( then press RETURN to complete the segment update even if you did not change anything … repeat
the process for all segments)
2. Ramp Rate:
Segment type
ramp rate
Target setpoint
139.5 F (this value would be 59.7 C)
Segment ramp rate
60.000 F
Auto Hold Type
Below Setpoint
Auto Hold Band Val 1.0 F
Event 1
Active
Event 2
Inactive
Event 3
Active
Event 4
Inactive
Event 5
Inactive
(press RETURN to complete)
3. Dwell:
Segment type
Dwell
Dwell at 139.5 for
01:00:00
Содержание Platinum Series
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...