[12]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
The Pasteurizer is equipped with a cord having an equipment
grounding conductor and a grounding plug.
BEFORE
INSERTING THE PLUG, MAKE CERTAIN THAT THE
ROCKER SWITCH IS SET TO “OFF” OR THE PUSH
BUTTON SWITCH IS IN THE POPPED OUT POSITION.
The plug must be inserted into an appropriate outlet that is
installed and grounded in accordance with all local codes and
ordinances. DO NOT modify the plug provided with the
Pasteurizer; if it will not fit the receptacle, have a proper outlet
or new plug end installed by a qualified electrician.
DO NOT TURN THE PASTEURIZER
ON UNTIL YOU ARE TOLD TO DO SO.
FAILURE TO FOLLOW THIS
INSTRUCTION MAY DAMAGE THE
UNIT AND VOID THE WARRANTY.
External Fuse Board
The unit is equipped with 3 external fuses on the back of the
unit. These fuses protect delicate electronics and also serve as
a troubleshooting guide in cases of system malfunction. The
layout of the fuses is shown below, as well as on the unit itself.
Refer to Trouble Shooting for further information.
AT FIRST USE OF THE MACHINE.
The system must be charged with water to prevent damage to
the heating elements. Once the installation is completed, place
a couple of gallons of very hot water into the milk tank. Then
follow the steps below for using the pasteurizer but
CHOOSE
THE COLOSTRUM COOL ONLY PROFILE FOR THE
FIRST USE OF THE MACHINE.
This will call for cooling
water to fill the tank of the machine. It may take several
minutes for the tank to fill with water. Once water is flowing
freely from the discharge line, this profile can be aborted as
described below. This step will not be necessary in future uses
unless the tank is drained.
Platinum Models use ¼ x 1 ¼ fuses
F3
Cold water valve
Fast-Acting 1/2A 250vac
F2
Motor
Fast-Acting 1A 250vac
F1
Main power supply
Fast-Acting 1A 250vac
WARNING: Component Ratings
West Control: 120-240vac, 1amp, 1P, 50-60Hz
YN80 Gear Motor: 156RPM, 120vac, 1P, 1amp, 60Hz
YN80 Direct Drive motors: 225RPM, 240vac, 1P,
1amp, 50-60Hz
Heater
DT10G:
L10A8-1E24, 1500watt, 240vac,
1P/3P, 14 amp, 50-60Hz
Heater
DT30G:
N14A20-1E24, 2000watt, 240vac,
18amp,1P/3P, 50-60Hz
Heater
DT60G
: N24-A23, 3900watt, 240vac, 34amp,
1P/3P, 50-60Hz
Cooling Fan: 670-OA825AP111WB, 120vac, 1P,
.5amp, 50-60Hz
Содержание Platinum Series
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...