Service Manual:

 DT10G, DT30G &DT60G 

HEATING ELEMENTS

: The heater elements 

are replaced when necessary by removing the 
back panel after disconnecting all power to the 
unit. Electrical connections to the elements are 
disconnected from the contactor. Remove the 
cotter pin or anti-vibration compound that 
keeps the element in the tube and pull the 
element out of the SS sheath enclosure in the 
water tank. New elements should be handled 
minimally to avoid rubbing off the white 
powder coating. Simply press in as far as 
possible and replace the friction pin if there is 
one present.  Reconnect the wires at the same 
locations on the contactor.

 

 

 
4.

 

Milk does not get to temperature but the 
Heater is hot. 

a.

 

There are two active heating 
elements (the third one in the center 
is a spare unless it is a 3 phase 
application in Europe then all 3 are 
used) and it is possible that only one 
is operable. Check resistance on 
each element with the power off to 
determine if one needs replacing. 

b.

 

Make certain that the agitator motor 
is turning during the cycle. It should 
be on during heating, timing, and 

cooling cycles. Replace if it is not 
working.  

c.

 

Check the bottom of the milk tank 
to make certain that it is being 
cleaned properly after each use. If 
there is milk build up or significant 
sticking, the unit is not being 
cleaned properly and heat transfer 
will be decreased, but more 
importantly, this is a prime 
opportunity for pathogens to grow. 

d.

 

Milk level is not high enough. The 
thermocouple needs to be fully 
covered in milk as it measures milk 
temperature at the tip. Also, too 
little milk will not allow optimal 
stirring which will decrease heat 
transfer and give false temperature 
readings. 

e.

 

Cold water is coming into the 
system. If there is a leak in the 
system, such as a leaking cold water 
solenoid valve, the heater cannot 
keep up and the milk will not heat 
properly. Repair the leak or replace 
the valve. 

 
 
5.

 

Water is leaking out the bottom of the Unit 

a.

 

Look under the machine on the 
sloping back floor, right side as you 
face the machine from the front. 
There is a pressure relief valve 
located here that will purge water if 
the drain line becomes occluded or 
pressures to the tank are too high. 
Check that the line is not blocked or 
kinked. See diagram below 

Содержание Platinum Series

Страница 1: ...1 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G Operator Manual Platinum Series Pasteurizers Models DT10G DT30G DT60G...

Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...

Страница 3: ...medical ISM radio frequency equipment Group 2 Class A EN 61000 6 2 1999 Electromagnetic Compatibility Generic Standards Immunity for Industrial Environments NOTE 1 This equipment must be installed and...

Страница 4: ...ing the DT60G 8 Mounting the Control Panel 8 Mounting the DT10G onto the Base 9 Lid Storage 9 Connecting the Milk Spigot 10 Choosing and Preparing a Location 10 Criteria for Selecting a Location 10 Co...

Страница 5: ...rofile 25 Instructions for downloading a new profile to your Dairy Tech Pasteurizer from a USB memory stick 25 Control Configuration 26 HOW TO CHANGE FROM FAHRENHEIT TO CELCIUS 27 IF TEMPERATURE NEEDS...

Страница 6: ...MMON SENSE CAUTION AND CAREFULNESS ARE FACTORS WHICH CANNOT BE BUILT INTO THE PASTEURIZER THESE FACTORS MUST BE SUPPLIED BY THE PERSON S INSTALLING MAINTAINING OR OPERATING THE PASTEURIZER Under no ci...

Страница 7: ...Surfaces include the lid plumbing fixtures electrical fixtures hoses heater body milk cabinet surfaces draining water and the milk or colostrum Touching these surfaces during operation may result in s...

Страница 8: ...he DT60G which has side mounting screws to secure the control box to the top of the cabinet The motor shaft must also be attached by inserting it through the side entry of the coupler followed by righ...

Страница 9: ...wder coated box and set the DT10G to the side Turn the white box over and move it to the location where you wish to install the machine Lift the pasteurizer and place it on the box so that the sides a...

Страница 10: ...0vac for control power in models where necessary e Floor space requirements are approx 1 yd 1M f Avoiding extremely drafty areas will improve heating efficiency of the unit g Always have 2 people lift...

Страница 11: ...CONNECTIONS SHOULD BE PERFORMED BY AN ELECTRICIAN OR OTHER TRAINED PERSONNEL The receptacle should be sharing minimal usage with other equipment to avoid unexpected outages and tripping of the breaker...

Страница 12: ...e Shooting for further information AT FIRST USE OF THE MACHINE The system must be charged with water to prevent damage to the heating elements Once the installation is completed place a couple of gall...

Страница 13: ...inate the product with bacteria from the bottom and sides of the bottles Always wear nitrile or latex gloves when handling the milk or colostrum to prevent the spread of pathogens from the skin surfac...

Страница 14: ...select a profile that you wish to run then press the return arrow key FOR THE FIRST USE OF THE MACHINE SELECT THE COLOSTRUM COOL ONLY PROFILE FOLLOW OTHER INSTRUCTIONS ON PREVIOUS PAGE You will be as...

Страница 15: ...memory remaining or power of outputs LED red lights in top indicate outputs for heating cooling and stirring of the product Main Numbers are the temperatures displayed in F or C The Dairy Tech ProVu c...

Страница 16: ...ir instructions What if the milk becomes spoiled before I pasteurize it This condition is fairly common and can happen at times even when the same successful routines have been followed There are spoi...

Страница 17: ...ze colostrum NO When done properly colostrum can be successfully pasteurized to eliminate the same pathogens that can be found in the milk They are even more dangerous in colostrum since these bacteri...

Страница 18: ...he system checked by a certified electrician before operating c Check the 1amp fuse F1 Make sure there is 115vac to and through the fuse If not replace with appropriate fuse DO NOT REPLACE WITH OVERSI...

Страница 19: ...s at the A1 and A2 tabs black and white 16awg wires on the back top of the contactor to see if it is being signaled by the SS relay If there is 115vac signal but no activation of the contactor replace...

Страница 20: ...tor is turning during the cycle It should be on during heating timing and cooling cycles Replace if it is not working c Check the bottom of the milk tank to make certain that it is being cleaned prope...

Страница 21: ...in the control for the cycle to initiate i During cooling with the 2 LED on the control lit up Is there power to the solenoid valve If the power is on and the machine has water but it will not flow re...

Страница 22: ...d or congealed a The most common cause for milk or colostrum to separate or congeal is acidification of the milk caused by two processes i Fermentation of the milk by bacteria will cause the release o...

Страница 23: ...failure This will also occur if someone shuts the unit off prior to completion of its assigned cycles and the unit will automatically restart when the toggle switch or power is restored If a long time...

Страница 24: ...profiles must individually be changed to Celsius as well This is not automatic for the profiles Decimal Point Position 123 4 Scale Input Range Lo Limit 0 make sure it is 0 when in Celsius Scale Input...

Страница 25: ...r has configured your memory stick with the appropriate files so that it can handle data that is usable by the control Remove the memory stick hold the enter button and press the up arrow twice to ret...

Страница 26: ...old the RETURN button and press the UP ARROW one time Then use the DOWN ARROW to scroll to configuration menu Press the RETURN button and enter the unlock code which is 10 by scrolling with the UP ARR...

Страница 27: ...ine is first turned on hold the RETURN button and press the UP ARROW one time Then use the DOWN ARROW to scroll to configuration menu Press the RETURN button and enter the unlock code which is 10 by s...

Страница 28: ...this 1 Step 2 Ramp Rate 3 Dwell 4 Ramp Time 5 End Select a segment by highlighting it then RETURN Here is a list of how the settings should appear in each of those segments Other profiles will have di...

Страница 29: ...amp Time Segment type ramp time Target setpoint 90 0 F this is the cool point Segment ramp time 00 00 02 Auto hold type above setpoint Auto hold band value 2 0 F Event 1 Active Event 2 Active Event 3...

Страница 30: ...access the controller main menu for milk heater temperature settings as well as process timing follow these steps Accessories Contact Dairy Tech Inc Dairy Tech Inc 34824 CR 29 Greeley CO 80631 Phone...

Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...

Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...

Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...

Страница 34: ...34 Rev 4 15 14 NOTES...

Страница 35: ...er 220vac 30amp dryer cord ME CordGrip1 1 power cord grip ME Fan 3 125 axial fan 115VAC 34CFM 12 leads ME FanFilter Fan Filter Washable Aluminum ME FuseHold fuse holder 16a 1 4 x 1 4 ME MotorGear120 r...

Страница 36: ...r 220vac 30amp dryer cord ME CordGrip1 1 power cord grip ME Fan 3 125 axial fan 115VAC 34CFM 12 leads ME FanFilter Fan Filter Washable Aluminum ME FuseHold fuse holder 16a 1 4 x 1 4 ME MotorGear120 re...

Страница 37: ...Spigot custom flanged spigot 1 SS MP ValRelief purge valve 4 psi MP ValveClamp1 1 SS valve clamp MP ValveSS1 304SS 1 25 sanitary butterfly valve JE element 24 cartridge heating element 3900watt 3 4 di...

Страница 38: ...38 Rev 4 15 14...

Отзывы: