Main Functions
Part 4 Functions and Control
41
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
Notes on Energy saving operation
If no presence detected in the room for 20 minutes, the energy saving operation will start, and
the INTELLIGENT EYE lamp goes off.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy
saving operation terminates.
This operation changes the temperature by –3.6°F (–2.0°C) in HEAT / +3.6°F (+2.0°C) in COOL
/ +3.6°F (+2.0°C) in DRY operation from the set temperature.
When the room temperature exceeds 86°F (30.0°C), the operation changes the temperature by
+1.8°F (+1.0°C) in COOL / +1.8°F (+1.0°C) in DRY operation from the set temperature.
This operation decreases the airflow rate slightly in FAN operation only.
Notes on INTELLIGENT EYE operation
Application range is as follows.
The air conditioner may switch to the energy-saving operation even if there are people in the
areas.
This may occur depending on the clothes the people are wearing, if there is no movement of the
people in the areas.
The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off
of mirrors as passers-by.
The sensor may not detect moving objects further than 23ft (7m) away. (Please see the
application range)
Sensor detection sensitivity changes according to the indoor unit location, the speed of
passers-by, temperature range, etc.
NIGHT SET mode will not switch on during use of INTELLIGENT EYE operation.
90°
55°
23ft (7m)
55°
Vertical angle 90°
(Side view)
Horizontal
angle 110°
(Top view)
23ft (7m)
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...