SiUS042113E
Main Functions
Part 4 Functions and Control
51
Note(s)
1.17 CLEAN Operation
Outline
The CLEAN function dries the interior of the indoor unit to reduce the amount of condensation
present. When COOL or DRY operation is performed, condensation may occur inside the air
conditioner. It is recommended to dry the inside of the air conditioner using CLEAN operation.
Details
To operate automatically
1. Press and hold
Menu (push 2sec)
button for 2 seconds.
2. Press
Select
▲ or
Select
▼ button to select menu number
2
.
Mold proof icon appears and
2
blinks.
3. Press
Menu (push 2sec)
button to confirm the select setting.
4. Press
Select
▲ or
Select
▼ button to change the setting as follows:
R4003797
5. Press
Menu (push 2sec)
button again.
Automatic CLEAN operation will be enabled or disabled according to the chosen setting.
If automatic CLEAN operation is enabled, CLEAN icon appears on the LCD and the CLEAN
PROOF lamp lights green when CLEAN operation is in progress.
R4003798
6. Press
Cancel
to return to the default screen.
Note on CLEAN setting
The display automatically returns to the default screen after 60 seconds. To return to the default
screen sooner, press
Cancel
button twice.
Notes on CLEAN operation
When you want to stop CLEAN operation midway, press
ON/OFF
button twice.
After DRY or COOL operation stops, the air conditioner starts CLEAN operation automatically,
and then stops automatically 140 minutes later.
This operation dries the inside of the air conditioner using FAN operation and HEAT operation.
The indoor temperature and humidity may not suit your preferences.
The CLEAN function dries the interior of the indoor unit to reduce the amount of condensation
present.
CLEAN operation is not available when the unit is turned off using the OFF TIMER or turned off
using a smartphone.
The flaps may sometimes close to increase the drying effect inside the air conditioner.
CLEAN operation automatically dries the inside of the air conditioner each time after COOL and
DRY operation is stopped.
CLEAN operation may not be performed if the COOL or DRY operation time is short.
If CLEAN operation does not suit your preference, set operation to “OFF”.
Automatic operation is disabled
(default)
Automatic operation is enabled
Display
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...