Outdoor Unit
SiUS042113E
20
Part 3 Printed Circuit Board Connector Wiring Diagram
Caution
2. Outdoor Unit
2.1 09/12 class
Main PCB (A1P)
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1)
S20
Connector for electronic expansion valve coil
2)
S40
Connector for overload protector
3)
S70
Connector for DC fan motor
4)
S80
Connector for four way valve
5)
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge
pipe temperature)
6)
S97
Connector for liquid pipe thermistor
7)
HL1, HN1, S
Wire harness for terminal strip
8)
E1, E2
Wire harness for earth/ground wire
9)
U, V, W
Wire harness for compressor
10)
FU1, FU2
Fuse (3.15 A, 250 V)
11)
FU3
Fuse (30 A, 250 V)
12)
LEDA
LED for service monitor (green)
13)
V1, V2, V3
Varistor
14)
J4
Jumper for facility setting
Refer to page 153 for details.
15)
J9
Jumper for drain pan heater
Refer to page 154 for details.
2P628602-1
LEDA
FU1
FU3
FU2
S90
S40
S20
S70
V2
V3
V1
S80
S97
E2
E1
HN1
S
HL1
W
V
U
J9
J4
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...