Troubleshooting
SiUS042113E
118
Part 6 Service Diagnosis
Reference
Reference
Reference
Reference
Reference
Troubleshooting
Check No.01
Check No.12
Check No.17
Check No.18
Check No.19
(R20418)
Caution
Replace the o
u
tdoor fan
motor.
Reconnect the connector or
fan motor lead wires.
Replace the stop valve.
Replace the o
u
tdoor heat
exchanger thermistor.
Replace the o
u
tdoor
u
nit
PCB (main PCB).
Replace the electronic
expansion valve or the coil.
Replace the o
u
tdoor
u
nit
PCB (main PCB).
Change the installation
location or direction.
Clean the o
u
tdoor heat
exchanger.
Check the installation space.
NG
OK
OK
NG
NG
OK
OK
OK
NG
NG
Check No. 19
Check the o
u
tdoor fan.
Check No. 18
Check the discharge
press
u
re.
Check No. 12
Check the electronic
expansion valve.
Check No. 01
Check the o
u
tdoor heat
exchanger thermistor.
Check No. 17
Check the installation
condition.
Be s
u
re to t
u
rn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...