![Daikin FTXM-V Series Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/daikin/ftxm-v-series/ftxm-v-series_service-manual_4700065145.webp)
SiUS042113E
Check
Part 6 Service Diagnosis
141
5.9 Installation Condition Check
Check No.17
1
2
3
4
5
6
7
320 VDC
(R25288)
S70
PCB
Act
u
al rotation p
u
lse inp
u
t (0 ~ 15 VDC)
Rotation command voltage (0 ~ 6.5 VDC)
Control voltage 15 VDC
Installation condition check
OK
Check the allowable
dimensions of the air
s
u
ction and
discharge area.
Is the airflow blocked by
obstacles or winds
blowing in the opposite
direction?
(R19394)
NG
YES
YES
NO
Is the discharged air
short-circ
u
ited?
NO
NO
YES
Is the o
u
tdoor heat
exchanger very dirty?
Change the installation
location or direction.
Change the installation
location or direction.
Clean the o
u
tdoor heat
exchanger.
Change the installation
location or direction.
Check the o
u
tdoor temperat
u
re.
(The o
u
tdoor temperat
u
re
sho
u
ld be within the operation
range.)
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...