9/10
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[C-05]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-06]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.I
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I
[C-09]
R/W
0: Normally open
1: Normally closed
9.I
[C-0A]
0
9.I
[C-0B]
0
9.I
[C-0C]
0
9.I
[C-0D]
0
9.I
[C-0E]
0
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart grid
9.I
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: Forced off
1: As normal
9.I
[D-07]
R/O
0: No
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
0
9.I
[E-02]
R/O
1: Heating only
9.I
[E-03]
R/O
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/O
0: No
1: Yes
9.I
[E-06]
R/O
0: No
1: Yes
9.I
[E-07]
R/O
1: Integrated
9.I
[E-08]
R/W
0: Disabled
1: Enabled
9.I
[E-09]
1
9.I
[E-0A]
0
9.I
[E-0B]
R/O
1: Yes
9.I
[E-0C]
0
9.I
[E-0D]
0
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
20
9.I
[F-02]
R/W
3~10°C, step: 1°C
3°C
9.I
[F-03]
R/W
2~5°C, step: 1°C
5°C
9.I
[F-04]
R/W
0: No
1: Yes
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
1
--
What is the thermo request contact type for the main zone?
Which heaters are permitted if prefer. kWh rate PS is cut?
--
--
--
--
Contact type of preferential kWh rate PS installation?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
Leaving water temperature compensation around 0°C.
--
Which type of DHW pump is installed?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
--
--
What is the indoor unit software type?
--
--
Is an external kWh meter used for power measurement?
Which type of compressor is installed?
Pump operation allowed outside range.
Is glycol present in the system?
--
--
Which type of unit is installed?
Power saving function for outdoor unit.
--
Is a demand PCB connected?
Is a bottom plate heater connected?
--
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Is a bi-zone kit installed?
--
Bottom plate heater ON temperature.
What is the number of backup heater steps?
Is the power saving function available on the outdoor unit?
Bottom plate heater hysteresis.
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
--
--
(*1) *3V_
(*2) *6V_
(*3) *9W
(#) Setting is not applicable for this unit.
4P629095-1A - 2021.02