3
|
Specific installer safety instructions
Installer reference guide
17
ERGA04~08EA + 08S18+23EA
Daikin Altherma 3 R F
4P629093-1A – 2021.11
Opening and closing the unit (see
"7.2 Opening and closing the units"
)
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover is removed.
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
Mounting the outdoor unit (see
"7.3 Mounting the outdoor unit"
WARNING
Fixing method of the outdoor unit MUST be in accordance with the instructions from
this manual. See
"7.3 Mounting the outdoor unit"
61].
CAUTION
Do NOT remove the protective cardboard before the unit is installed properly.
"7.4 Mounting the indoor unit"
WARNING
Fixing method of the indoor unit MUST be in accordance with the instructions from
this manual. See
"7.4 Mounting the indoor unit"
)
WARNING
Field piping method MUST be in accordance with the instructions from this manual.
See
70].
DANGER: RISK OF BURNING/SCALDING
WARNING
If the total refrigerant charge in the system is ≥1.84 kg (i.e. if the piping length is
≥27 m)
, you need to comply with the minimum floor area requirements for the
indoor unit. For more information, see
"7.1.3 Installation site requirements of the
WARNING
▪
Only use R32 as refrigerant. Other substances may cause explosions and
accidents.
▪
R32 contains fluorinated greenhouse gases. Its global warming potential (GWP)
value is 675. Do NOT vent these gases into the atmosphere.
▪
When charging refrigerant, ALWAYS use protective gloves and safety glasses.
Содержание EHVZ04S18EA6V
Страница 269: ......
Страница 270: ......
Страница 271: ......
Страница 272: ...4P629093 1A 2021 11 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...