Electrical installation
Installer reference guide
98
ERGA04~08EA + 08S18+23EA
Daikin Altherma 3 R F
4P629093-1A – 2021.11
2×
2
Remove the refrigerant piping cover.
1×
1
2
3
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
4
Connect the interconnection cable and power supply as follows. Ensure stress
relief by using the wire clamp.
a
c
d
1N~ 50 Hz
220-240 V
b
a
Interconnection cable
b
Power supply cable
c
Fuse
d
Earth leakage circuit breaker