SiUS30-604
Field Setting
Test Operation
119
3.2.2 Cool / Heat Mode Switching (In case of heating and simultaneous
cooling / heating) operation connection
Set Cool/Heat Separately for Each BS Unit by Cool/Heat Selector.
Set remote controller change over switch (SS1, SS2) as following:
•
When using COOL/HEAT selector, turn this switch to the BS side.
When using cool/heat selector, connect to the terminal A, B and C on the EC of the electric parts
box.
EXAMPLE OF TRANSMISSION LINE CONNECTION
•
Example of connecting transmission wiring.
Connect the transmission wirings as shown in the Fig. 1.
SS2
SS1
This setting must be completed
before turning power supply ON.
NOTE:
1
2
1
2
F2
B
C
A
F2
F1
F1
F2
F1
Outside unit
TO IN/D UNIT TO OUT/D UNIT
F1 F2
F1
F2
F1
F2
F1 F2
IN/D
OUT/D.BS
REMOTE
CONTROLLER
BS unit A
F1
F2
F1
F2
IN/D
OUT/D.BS
BS unit B
COOL/HEAT
selector
Branch wiring
Use 2-core wires.
(There is no polarity.)
B
C
A
REMOTE
CONTROLLER
COOL/HEAT
selector
Cool/heat selector remote
control wiring
Use 3-core wires.
(Keep in mind the polarity.)
F1
F2
F1
F2
IN/D
OUT/D.BS
B
C
A
REMOTE
CONTROLLER
Final BS unit
Indoor unit for cooling
F2
F1
COOL/HEAT
selector
Fig. 1
F2
F1
F2
F1
F1 F2
F1
F2
F1
F2
IN/D
OUT/D.BS
F1 F2
F1
F2
OUT/D.BS
To the indoor unit where
the selection of heating
and cooling is available.
Final BS unit
In case of the indoor unit connect as the cool-only unit, it wire
he terminal
of the last BS unit.
Cooling only
1st unit
Final unit
Содержание BSVQ36MVJU
Страница 1: ...SiUS30 604 Water Cooled Inverter Series Heat Pump Heat Recovery 60Hz ...
Страница 7: ...SiUS30 604 vi Table of Contents Index i Drawings Flow Charts v ...
Страница 13: ...Introduction SiUS30 604 xii ...
Страница 27: ...Capacity Range SiUS30 604 14 General Information ...
Страница 49: ...Specifications SiUS30 604 36 Specifications ...
Страница 61: ...Refrigerant Flow for Each Operation Mode SiUS30 604 48 Refrigerant Circuit ...
Страница 67: ...SiUS30 604 54 Function 9 8 Heater Control 90 9 9 List of Swing Flap Operations 91 9 10 Freeze Prevention 92 ...
Страница 271: ...Procedure for Mounting Dismounting of Switch Box SiUS30 604 258 Procedure for Mounting Dismounting of Switch Box ...
Страница 276: ...SiUS30 604 Piping Diagrams Appendix 263 1 3 BS Unit BSVQ36MVJU BSVQ60MVJU 4D045338 ...
Страница 279: ...Wiring Diagrams SiUS30 604 266 Appendix RWEYQ60 72 84 144 168 216 252MTJU Operation System Heat Pump 3D055419 ...
Страница 281: ...Wiring Diagrams SiUS30 604 268 Appendix FXSQ12M 18M 24M 30M 36M 48MVJU FXMQ30M 36M 48MVJU 3D043177A 3D043176A ...
Страница 282: ...SiUS30 604 Wiring Diagrams Appendix 269 FXAQ07M 09M 12M 18M 24MVJU FXHQ12M 24M 36M 3D046039C 3D048116 ...
Страница 283: ...Wiring Diagrams SiUS30 604 270 Appendix FXLQ12M 18M 24MVJU FXNQ12M 18M 24MVJU 3D045644A ...
Страница 284: ...SiUS30 604 Wiring Diagrams Appendix 271 2 4 BS Unit BSVQ36M 60MVJU 3D045069A ...
Страница 289: ...Option List SiUS30 604 276 Appendix 4 Option List 4 1 Optional Accessories Outside Unit 3D055420 ...
Страница 305: ...Precautions for New Refrigerant R 410A SiUS30 604 292 Precautions for New Refrigerant R 410A ...
Страница 309: ...SiUS39 601 iv Index ...