8
|
Electrical installation
Installer reference guide
82
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Item
Description
Current sensors
See the installation manual of the current
sensors.
Wires: 3×2. Use part of the cable (40 m)
delivered as accessory.
[9.9.1]=3 (
Power consumption control
=
Current sensor
)
[9.9.E]
Current sensor offset
Human Comfort Interface
See:
▪
Installation and operation manual of the
Human Comfort Interface
▪
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9]
Control
[1.6]
Room sensor offset
8.2.1 To connect the main power supply
Use one of the following layouts to connect the power supply (for details of C1~C5,
see below the table):
#
Layout
Open the unit
(a)
1 Single cable power supply (= combined power
supply)
C1
C1
: Power supply for the backup heater, and the
rest of the unit (1N~ or 3N~)
Not necessary
(connection to factory-
mounted cable outside
of the unit)
2 Dual cable power supply (= split power supply)
Note:
This is for example needed for installations
in Germany.
C1
C5
C1
: Power supply for the backup heater (1N~ or
3N~)
C5
: Power supply for the rest of the unit (1N~)
4
3
2
1
Содержание Altherma 3 GEO
Страница 1: ...Installer reference guide Daikin Altherma 3 GEO EGSAH06UDA9W EGSAH10UDA9W EGSAX06UDA9W EGSAX10UDA9W ...
Страница 248: ...11 11 ...
Страница 249: ......
Страница 250: ......
Страница 251: ......
Страница 252: ...4P598592 1A 2019 12 Copyright 2019 Daikin Verantwortung für Energie und Umwelt ...