8
|
Electrical installation
Installer reference guide
88
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Q2DI
L
N
1N~, 50 Hz, 230 V AC
F2B
1
3
2
4
I
I
BRN
BLU
YL
W/GRN
Z15C
N=1
2
3
X22YB
1
X22Y
Z2F/1
Z2F/2
Z2F/3
EKGSPOWCAB
F2B
Overcurrent fuse (field supply). Recommended fuse: 2‑pole, 16 A fuse, C curve.
Q2DI
Earth leakage circuit breaker (field supply)
Configuration power supply
[9.3]
Backup heater
[9.8]
Benefit kWh power supply
8.2.2 To connect the remote outdoor sensor
The remote outdoor sensor (delivered as accessory) measures the outdoor
ambient temperature.
INFORMATION
If the desired leaving water temperature is weather dependent, the full time outdoor
temperature measurement is important.
Remote outdoor cable (40 m) delivered as accessory
[9.B.2]
Ext. amb. sensor offset
(= overview field setting [2‑0B])
[9.B.3]
Averaging time
(= overview field setting [1‑0A])
1
Connect the external temperature sensor cable to the indoor unit.
a
c
d
b
a
Factory-mounted cable
b
Splicing connectors (field supply)
c
Remote outdoor sensor cable (40 m)(delivered as accessory)
d
Remote outdoor sensor (delivered as accessory)
2
Fix the cable with cable ties to the cable tie mountings.
Содержание Altherma 3 GEO
Страница 1: ...Installer reference guide Daikin Altherma 3 GEO EGSAH06UDA9W EGSAH10UDA9W EGSAX06UDA9W EGSAX10UDA9W ...
Страница 248: ...11 11 ...
Страница 249: ......
Страница 250: ......
Страница 251: ......
Страница 252: ...4P598592 1A 2019 12 Copyright 2019 Daikin Verantwortung für Energie und Umwelt ...