10
|
Configuration
Installer reference guide
176
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
WD curve type
The weather dependent curve can be set using the
2-points
method or the
Slope-Offset
method. For more information about each method, see
142] and
143]. The curve type in the
menu is read only, and will correspond to the curve type set for the main zone.
Changing the curve type for the additional zone must be done in the main zone
WD
curve type
[2.E] menu. See
150] for more information.
#
Code
Description
[5.E]
N/A
▪
0:
2-points
▪
1:
Slope-Offset
WD curve
When weather dependent operation is active the desired tank temperature is
determined automatically depending on the averaged outdoor temperature: low
outdoor temperatures will result in higher desired tank temperatures as the cold
water tap is colder and vice versa.
In case of
Schedule only
or
Schedule + reheat
domestic hot water
preparation, the storage comfort temperature is weather dependent (according to
the weather dependent curve), the storage economic and reheat temperature are
NOT weather dependent.
In case of
Reheat only
domestic hot water preparation, the desired tank
temperature is weather dependent (according to the weather dependent curve).
During weather dependent operation, the end-user cannot adjust the desired tank
temperature on the user interface. Also see
142] and
143].