9
|
LAN adapter
Installer reference guide
126
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Possible causes
Corrective action
The configuration web interface is ONLY
available for 2 hours after every power
reset. Its timer can have run out.
Perform a power reset on the LAN
adapter.
The LAN adapter is NOT connected to
the network (network connection LED
NOT blinking).
Connect the LAN adapter to a router.
The LAN adapter is NOT connected to
the router or the router does NOT
support DHCP.
Connect the LAN adapter to a router
that supports DHCP.
The computer is NOT connected to the
same router as the LAN adapter.
Connect the computer to the same
router as the LAN adapter.
INFORMATION
If none of the corrective actions work, try performing a power reset of the total
system.
Symptom: The app does not find the LAN adapter
In the rare case that the Daikin Residential Controller app does not find the LAN
adapter automatically, connect router, LAN adapter, and app manually by way of a
fixed IP address.
1
In the router, check the IP address that is currently assigned to the LAN
adapter.
2
Access the configuration web interface with this IP address.
3
On the configuration web interface, set "DHCP active" to "Manually".
4
In the router, assign a static IP address to the LAN adapter.
5
On the configuration web interface, in the fields next to "Static IP address", set
the same static IP address.
6
In the Daikin Residential Controller app (Settings menu), assign the same IP
address to the LAN adapter.
7
Reset the power to the LAN adapter.
Result:
Router, LAN adapter, and Daikin Residential Controller app share the same
fixed IP address and should be able to find each other.
9.6.3 Solving problems based on error codes – LAN adapter
Error codes of the indoor unit
If the indoor unit loses its connection with the LAN adapter, the following error
code appears on the user interface:
Error code
Description
U8-01
Connection with LAN adapter lost
Error codes of the adapter
LAN adapter errors are indicated by the status LEDs. There is a problem if one or
more status LEDs have the following behaviour: