S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
126
6.7.2.58 F73: Interval function Arc OFF time
Sets the arc-OFF time in the Interval function.
•
Set the arc-OFF time in the range of 0.20 to 9.99 seconds.
6.7.2.59 F75: Wire inching initial speed
Sets the initial speed (first second) of wire inching when the value is set other than 0.
After 1 second has passed, the feed speed shifts to the normal inching speed.
•
If the set initial speed is greater than the normal inching speed, the normal inching speed is prioritized as the initial
speed.
6.7.2.60 F76: Wire feeder select
Select the wire feeder to use with the welding power source.
•
[ON]: CM-0401-D
•
[OFF]: CM-7403
6.7.2.61 F77: Welding power source identification numbers
Sets the identification numbers of welding power source when using welding result control function. The identification
number set in this function become the part of file name when backing up the data of welding result control function.
(
Welding Result Control Function)
•
Setting range of identification number: 1 to 999.
6.7.2.62 F78: Prevention of unintended torch switch operation
Sets whether or not to output the error code when welding is not performed for a certain time after the pre-flow to avoid
an unexpected torch switch operation.
•
[ON]: If welding is not performed for five seconds after the pre-flow, Error code "E-011" is displayed on the touch
panel and the output of the welding power source stops.
•
[OFF]: disables the function. (
6.7.2.63 F79: Switching of CAN communication connection device
Set the connection device to be used for the CAN communication.
Set to [0] to use the Digital Remote Control Box.
Set to [1] to use the Digital panel (Attached to the wire feeder) and Intelli torch.
Set to [2] to use the Digital pull torch.
Set to [3] to use the Digital middle feeder.
* The Digital panel can also be used with [2] and [3].
This function is effective when any one of "0" (Semi-auto mode), "1" (Automatic machine 1 mode), and "2" (Automatic
machine 2 mode) is selected for F4 (Auto/Semi-auto mode).
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...