Chapter 6
W
elding Condition
6.7.2.4
F5: Maximum external command voltage
When the internal function F4 (Auto/Semi-auto mode) is used with the setting of "1", set the maximum value of command
voltage input from outside.
Select either from 10 V, 14 V, or 15 V.
The below charts show the relationship between current/voltage command voltage and welding current/voltage.
(Use these charts as a rough indication. Welding current/voltage against the welding JOB setting voltage may differ from
the indications on the charts depending on the external input (command voltage), wire length or routing of the cable at
base material side/torch side, or wire feeding length difference.)
•
ARXIS WB-P403L
•
ARXIS WB-P503L
6.7.2.5
F6: Upslope time
When the difference between the initial current and welding current is large, the wire may burn up at the change of the
conditions. In this case, adjust the time period changing from the initial current to the welding current (upslope time)
longer.
•
Setting range of upslope time: 0.0 to 10.0 [sec]
6.7.2.6
F7: Downslope time
When the difference between the welding current and crater current is large, the wire may plunge into weld pool at the
change of the conditions (the wire is fed by inertia because the speed reduction is too late). In this case, adjust the time
period changing from the welding current to the crater current (downslope time) longer.
•
Setting range of downslope time: 0.0 to 10.0 [sec]
W
elding current (A)
External command voltage (V)
5
0
10
15
10 V
15 V
0
5
10
15
20
25
30
35
40
45
14 V
<Command voltage - Welding current characteristic>
<Command voltage - Welding voltage characteristic>
W
elding voltage (V)
External command voltage (V)
0
50
100
150
200
250
300
350
400
0
5
10
15
14 V
10 V
15 V
welding except TIG welding is 20 A.
The minimum value of the voltage for the
0
50
100
150
200
250
300
350
400
450
500
550
W
e
lding current (A)
External command current (V)
5
0
10
15
10 V
15 V
0
5
10
15
20
25
30
35
40
45
50
14 V
<Command voltage - Welding current characteristic>
<Command voltage - Welding voltage characteristic>
W
elding voltage (V)
External command voltage (V)
5
0
10 V
10
15
15 V
14 V
welding except TIG welding is 20 A.
The minimum value of the voltage for the
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...