S
ETTING
W
ELDING
JOB
W
ELDING
C
ONDITION
C
HAPTER
6
93
Chapter 6
W
elding Condition
6.6.4.3
4T (Crater "ON") (no start condition)
Select "4T" by the 2T/4T menu and select "START CONDITION OFF" by the Start Condition menu.
•
Carry out twice the ON/OFF operation of the torch switch and carry out the welding operation. In the second ON
operation, the welding sequence is carried out by the crater current.
•
Even if the torch switch is switched off during welding, the signal will be self-hold. (The torch switch should remain
depressed and held during the CRATER phrases.)
•
When selecting "4T/Crater DC"
Regardless of the setting by the WELDING PROCESS menu, the machine automatically turns to the welding with no
pulse when the crater-fill process starts.
•
When selecting "4T/Crater DC Pulse"
When "DC PULSE" or "DC WAVE PULSE" is selected by the WELDING PROCESS menu, the machine automatically
turns to the pulse welding mode when the crater-fill process starts.
ON
OFF
Crater-fil
㼘
ON
OFF
Crater-fill current
ON
OFF
ON
OFF
Torch switch
Gas flow
Output voltage
Wire feeding speed
Welding current
Main welding
Anti-stick time
Pre-flow
Post-flow
No-load voltage
Slow-down speed
Welding current
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...