L
IST
OF
W
ELDING
JOB
W
ELDING
C
ONDITION
C
HAPTER
6
66
F47
Special 2T crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the Special 2T.
(available when F45 is enabled)
○
F48
Adjusting current with torch
switch
OFF/ON
OFF
With the setting of "Crater" and in the welding condition
(during start input holding), sets whether to adjust
current by the torch switch operation:
OFF: not to use torch switch
ON: uses torch switch (increase/decrease volume set
by F49 and F50 are applied).
○
F49
Current increase and
decrease by single-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON" is
selected in F48)
○
F50
Current increase and
decrease by double-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by double-
clicking of the torch switch. (available when "ON" is
selected in F48)
○
F51
Special crater repeat
OFF/ON
OFF
With the setting of "4T," sets whether to switch the
welding condition and crater condition by the click
operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
○
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command / Feeding
command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current / Sequence
information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage / Sequence
information
7: Welding current / Feeding command / Sequence
information
8: Welding voltage / Feeding command / Sequence
information
-
F53
Sampling speed of data log
function
1/2/3
2
Sets sampling interval of the data log function:
1: 10 ms
2: 100 ms
3: 1 s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown speed
at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
F55
Arc outage detection time
0.01 to 9.99
3.00 (s)
The detection time to output the arc outage signal to the
external output terminal is set.
-
F56
Arc start failure detection time
0.01 to 9.99
3.00 (s)
The detection time to output the arc start failure signal
to the external output terminal is set.
F57
WCR output ON delay time
0.01 to 0.50 (s) /
OFF
OFF
When the welding current is applied, ON delay time is
set to WCR output signal.
The default value is set at the time of “OFF”. (The default
value is 0.003 seconds.)
F58
WCR output OFF delay time
0.10 to 0.50 (s)/
OFF
OFF
When arc outage occurs, OFF delay time is set to WCR
output signal.
The default value is set at the time of “OFF”. (0.1
seconds normally, 0.3 seconds during self holding)
F59
Analog setting switch
OFF (fixed)
OFF
Used when connecting with OTC automatic machine.
F60
Pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current in pulse
welding.
○
F61
Pulse peak time fine adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time in pulse
welding.
○
F62
Base current fine adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current in pulse
welding.
○
F63
L pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current at the
LOW side in pulse welding.
○
No.
Function Name
Setting range
Initial value
Explanation
Memory
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...