6.7.2.34 F49: Current increase and decrease by single-clicking
To increase/decrease the welding current by the torch switch operation, set the current increase/ decrease volume at
single-clicking. This function is available when the internal function F48 (Adjusting current with torch switch) is set to
[ON].
•
Set the current increase/decrease volume by single-clicking in the range of -100 to 100 A.
6.7.2.35 F50: Current increase and decrease by double-clicking
To increase/decrease the welding current by the torch switch operation, set the current increase/ decrease volume at
double-clicking. This function is available when the internal function F48 (Adjusting current with torch switch) is set to
[ON].
•
Set the current increase/decrease volume by double-clicking in the range of -100 to 100 A.
6.7.2.36 F51: Special crater repeat
In the sequence of main welding of the "4T/Crater repeat" (during start input holding), the torch switch operation can
switch the welding and crater treatment repeatedly as many times as needed.
•
[ON]: Setting of "4T/Crater repeat" is applied, and transits to the crater treatment by single-clicking of the torch switch
during the welding sequence (start input holding). It is available to return to the main welding as many times as
needed even after transit to the crater treatment by single-clicking of the torch switch.
When this function is enabled, "special crater (repeat)" is displayed in the HOME screen.
•
[OFF]: disables the function.
T I P S
•
When this function is set to [ON], automatically the setting of "4T/Crater repeat" is
selected, disabling other welding modes. (The 2T/4T menu does not work.)
•
Single-clicking operation should be within 0.3 seconds.
•
At the time of transition to crater, press the torch switch for at least 0.3 seconds.
•
Welding process at crater treatment is the same as that of main welding.
Example:
In the setting examples of Initial welding current: 80 A; Main welding current: 100 A; and Crater current: 60 A, the
following diagram is available:
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding JOB memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding JOB with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special 2T) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
100 A
80 A
60 A
100 A
60 A
Press 0.3 sec. or more
100 A
60 A
Single
(within 0.3 sec.)
ON
OFF
Torch switch
Welding current
Crater-fil
㼘
Main welding
Start condition
Crater-fil
㼘
Crater-fil
㼘
Main
welding
Main
welding
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...