S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
125
Chapter 6
W
elding Condition
6.7.2.52 F67: Setting change of current value (start condition, crater condition)
When "CRATER ON" is selected, the current value of the start condition and the crater condition can be set in percentage
based on the current value of the welding condition.
•
[ON]: enables the function.
Set the current value of the start condition with F68, and set the current value of the crater condition with F69.
•
[OFF]: disables the function.
6.7.2.53 F68: Setting of current value (start condition)
The current value of the start condition can be set in percentage based on the current value of the welding condition.
•
Setting range of current value (start condition): 10 % to 300
%
6.7.2.54 F69: Setting of current value (crater condition)
The current value of the crater condition can be set in percentage based on the current value of welding condition.
•
Setting range of current value (crater condition): 10 % to 300 %
6.7.2.55 F70: Upper limit setting for analog remote control
This function can be used for only DC TIG or MMA welding.
Sets the upper limit (the value when the knob is turned clockwise all the way) of the welding current adjustable by the
analog remote control (optional accessory).
If it is difficult to perform fine current adjustment with the knob of the analog remote control when welding in the low
current region, fine current adjustment will be easier if this function is used to lower the upper limit.
•
Setting range of the value:
20 to 400 A (ARXIS WB-P403L)
20 to 550 A (ARXIS WB-P503L)
6.7.2.56 F71: Interval function
This function repeats arc ON/OFF to control the heat input.
•
[ON]: Enables the function. When this function is enabled, ": Interval" will be displayed at the end of CRATER-FILL
CONDITION in the Home screen, and internal functions F72 and F73 will be enabled.
(Example) 2T: Interval
•
[OFF]: Disable the function.
T I P S
•
When this function is set to "ON", the setting of "2T" will be selected automatically, disabling
other welding modes. (The 2T/4T menu will not function.)
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding JOB memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding JOB with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special 2T) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
6.7.2.57 F72: Interval function Arc ON time
Sets the arc-ON time in the Interval function.
•
Set the arc-ON time in the range of 0.20 to 9.99 seconds.
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...