Figure 5-65 In area No.
Step 2
Click
to add the people counting function.
Step 3
Double-click the name to modify the rule name. Select People Counting or In Area No.
●
People Counting : The system counts the people entering and leaving the detection
area. When the number of counted number of people who enter, leave, or stay in the
area exceeds the configured value, the system performs an alarm linkage.
●
In Area No. : The system counts the people in the detection area and the duration that
people stay in the area. When the number of counted number of people in the
detection area or the stay duration exceeds the configured value, the system performs
an alarm linkage. This function is available on some select models.
Step 4
Click Draw Area to draw a detection area in the image.
●
When setting People Counting, you need to draw direction lines. When targets enter
or leave along the direction line, they will be counted.
●
For the models that support multiple counting rules, different detection areas can be
overlapped.
Step 5
Set parameters.
Operation Manual
190
Содержание IPC-HFW2431T-ZS-S2
Страница 1: ...ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 1 8 Network Camera Web 3 0 Operation Manual...
Страница 105: ...Figure 4 82 SNMP 1 Figure 4 83 SNMP 2 Operation Manual 94...
Страница 127: ...Figure 4 103 Add user operation permission Operation Manual 116...
Страница 158: ...Figure 5 17 Manual calibration 1 Operation Manual 147...
Страница 196: ...Figure 5 60 Search results face recognition Figure 5 61 MoreInfo face recognition Operation Manual 185...
Страница 200: ...Procedure Step 1 Select Setting Event People Counting Figure 5 64 People counting Operation Manual 189...
Страница 247: ......