Figure 5-19 Alarm track
Step 2
Select the Enable check box to enable track linkage.
After enabling the function, manual positioning, manual tacking and auto tracking take
effect.
Step 3
Set parameters.
Table 5-3 Description of alarm track parameters
Parameter
Description
Auto Track
Select On, and the speed dome automatically links to a corresponding
position and tracks an object when the intelligent rules of the
panoramic camera trigger alarms.
Track Time
Set the alarm track time.
●
Before an object disappears: The speed dome would automatically
link to a corresponding position and tracks an object until the
object moves out of the monitoring range when the intelligent
rules of the panoramic camera trigger alarms.
●
Custom: Set the auto alarm track time of the speed dome.
Idle Time
It is an interval from the end of alarm track of the speed dome to the
start of idle mode.
Set Idle Time and Idle Position. If no event needs to be tracked after
the configured idle time, the device automatically rotates to the set
idle position. For example, the Idle Time is set to be five seconds and
the Idle Position is set to be preset point 1. When the speed dome
does not start tracking after five seconds, it automatically rotates to
preset 1.
To set Idle Position, first set a preset point. For preset point, see
Idle Position
Step 4
Click Save.
Operation Manual
149
Содержание IPC-HFW2431T-ZS-S2
Страница 1: ...ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 1 8 Network Camera Web 3 0 Operation Manual...
Страница 105: ...Figure 4 82 SNMP 1 Figure 4 83 SNMP 2 Operation Manual 94...
Страница 127: ...Figure 4 103 Add user operation permission Operation Manual 116...
Страница 158: ...Figure 5 17 Manual calibration 1 Operation Manual 147...
Страница 196: ...Figure 5 60 Search results face recognition Figure 5 61 MoreInfo face recognition Operation Manual 185...
Страница 200: ...Procedure Step 1 Select Setting Event People Counting Figure 5 64 People counting Operation Manual 189...
Страница 247: ......