41
Positive Close
If enabled, the open and close gaps are ignored and the gate will stop touching the end stops. This is
usually used in conjunction with electric fencing where it is required that the gate stops against
contacts for the electric fence.
Positive Close Force
Sets the force the motor will exert on the end stop when it reaches it.
Minimum Reverse Limit
Sets the distance from the end stops in which the gate will do a full reverse if an obstruction is en-
countered in normal running mode.
Mains Fail Speed
Used to reduce the running speed of the gate should a mains failure occur. This conserves a small
amount of power and also provides a visible indication that the main power supply to the operator
motor is being interrupted.
Motor Direction
Reverses the motor direction without having to swap the motor wires around on the controller.
Slow Open Speed
Adjusts the speed that the operator will run at when running in Slow Speed in the open direction.
The operator runs in Slow Speed when programming the limits, when the controller detects a colli-
sion and during the Beam Reverse modes.
Slow Close Speed
Adjusts the speed that the operator will run at when running in Slow Speed in the closed direction.
The operator runs in Slow Speed when programming the limits, when the controller detects a colli-
sion and during the Beam Reverse modes.
USE FACTORY SETTING
Used to restore the Gate Setup to the factory default settings. This will not affect the remote and group
settings.
……..continued
HOLIDAY LOCKOUT
When enabled, Holiday Lockout will ignore all triggers received, no matter the origin. There are two methods of
activating Holiday Lockout:
Method 1
:
Connecting devices, such as a keypad or keyswitch, to the controller via the LCK/STP input.
Method 2
:
Program a remote button to the Holiday Lockout function (see Remote Settings pg. 30). Pressing the
learned remote button, or combination of buttons, will both activate and deactivate Holiday Lockout.
GROUND LOOP (Loop Detector)
Connected to the controller via the Loop input, a Ground Loop is commonly used for controlling vehicle access
(usually exiting), or to prevent a gate from closing on a vehicle. When a vehicle passes over the Ground Loop it
triggers the gate open. As long as the Ground Loop is active (ie detecting a vehicle) the gate with remain open.
ADDITIONAL FEATURES
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...