34
Alarm Duration
This setting adjusts the duration that the alarm output will remain active.
Hold Alarm
This setting will keep the alarm output activated for as long as an alarm condition persists. The alarm
output will only switch off after the alarm condition is removed and the alarm duration time has expired.
Rearm Duration
This setting prevents alarm conditions from continuously retriggering the alarm output. The alarm input
will only rearm after the alarm condition is removed and the Rearm Duration has expired.
Stand Open Time
This function sets the maximum length of time that the gate can stand open before the Gate Open Alarm
function is enabled thereby activating the alarm output. When setting the Stand Open Time, take into
consideration any Auto Close times set and the time required to enter or exit through the gate.
……..continued
LOCK SETTINGS
Electric Lock
This function enables the use of an electric lock with the operator (see pg. 26 for wiring diagram).
In the event that power to the gate operator is lost, the gate will remain locked and the electric lock will
have to be opened manually.
Magnetic Lock
This function enables the use of a magnetic lock with the operator (see pg. 26 for wiring diagram).
In the event that power to the gate operator is lost, the magnetic lock will automatically unlock.
Magnetic locks are not suitable for use with solar powered systems. Magnetic locks draw large amounts
of power which will significantly reduce the number of times the gate operator can be operated during a
power failure.
Enabling the Magnetic Lock function when using an Electric Lock will result in the Electric Lock being
damaged.
Off When Open
This function reduces power consumption of magnetic locks by switching the magnetic lock off while the
gate is open. The lock will only be switched on again when the gate is closed.
Pre Open Delay
This setting is used to create a short delay before the gate opens, during which time the lock will unlock.
This should be applied when using an electric lock to prevent the gate opening before the electric lock
has unlocked.
Post Open Delay
This setting allows the gate to move away from the ’locked’ position before the locked state is restored
to the lock. It is especially useful for magnetic locks that may pull the gate back if re energized before the
gate has moved far enough away from the locked position.
Pre Close Delay
This setting is only used where the gate is locked in the open position and needs to be released prior to
closing.
Post Close Delay
This setting keeps the lock unlocked for a short period after the gate starts closing. Used with magnetic
locks to prevent the gate from slamming shut while closing if the ‘Off When Open’ setting is not selected.
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...