Alarm Duration

 

This setting adjusts the duration that the alarm output will remain active.

 

Hold Alarm

 

This setting will keep the alarm output activated for as long as an alarm condition persists. The alarm 
output will only switch off after the alarm condition is removed and the alarm duration time has expired.

 

Rearm Duration

 

This setting prevents alarm conditions from continuously retriggering the alarm output. The alarm input 
will only rearm after the alarm condition is removed and the Rearm Duration has expired.

 

Stand Open Time 

 

This function sets the maximum length of time that the gate can stand open before the Gate Open Alarm 
function is enabled thereby activating the alarm output. When setting the Stand Open Time, take into 
consideration any Auto Close times set and the time required to enter or exit through the gate.

 

 

……..continued

 

 

LOCK SETTINGS

 

Electric Lock

 

This function enables the use of an electric lock with the operator (see pg. 26 for wiring diagram). 

 

In the event that power to the gate operator is lost, the gate will remain locked and the electric lock will 
have to be opened manually.

 

Magnetic Lock 

 

This function enables the use of a magnetic lock with the operator (see pg. 26 for wiring diagram). 

 

In the event that power to the gate operator is lost, the magnetic lock will automatically unlock.

 

Magnetic locks are not suitable for use with solar powered systems. Magnetic locks draw large amounts 
of power which will significantly reduce the number of times the gate operator can be operated during a 
power failure.

 

Enabling the Magnetic Lock function when using an Electric Lock will result in the Electric Lock being 
damaged.

 

Off When Open

 

This function reduces power consumption of magnetic locks by switching the magnetic lock off while the 
gate is open. The lock will only be switched on again when the gate is closed.

 

Pre Open Delay

 

This setting is used to create a short delay before the gate opens, during which time the lock will unlock. 
This should be applied when using an electric lock to prevent the gate opening before the electric lock 
has unlocked.

 

Post Open Delay

 

This setting allows the gate to move away from the ’locked’ position before the locked state is restored 
to the lock. It is especially useful for magnetic locks that may pull the gate back if re energized before the 
gate has moved far enough away from the locked position.

 

Pre Close Delay

 

This setting is only used where the gate is locked in the open position and needs to be released prior to 
closing.

 

Post Close Delay

 

This setting keeps the lock unlocked for a short period after the gate starts closing. Used with magnetic 
locks to prevent the gate from slamming shut while closing if the ‘Off When Open’ setting is not selected.

 

Содержание RT25/50

Страница 1: ...INSTALLATION USER MANUAL RT25 50 Regular Traffic 12V 24V 25 50m per min 500 300kg HT18 36 High Traffic 12V 24V 18 36m per min 600 300kg Ver 1 01 Proudly manufactured by www dace co za...

Страница 2: ...ams Relay Output 20 11 2 External Radio Receiver Loop Detector 21 11 3 Closing Safety Beam FET Output Relay Output 22 11 4 Opening Safety Beam FET Output Relay Output 23 11 5 Connecting Common Externa...

Страница 3: ...anual Take Careful Note Information that may affect the operator or function in a way you did not expect Good Idea Following this instruction might assist in the future or help with the installation W...

Страница 4: ...care should be taken when automating a gate that is fully cladded as wind resistance can cause the gate to not close properly Only when all the above points are satisfactory should you go ahead with i...

Страница 5: ...on of the equipment There are a number of areas that may cause entrapment which could lead to injury ULTIMA TECHNICAL SPECIFICATIONS continued AREAS WHERE INJURY OR ENTRAPMENT CAN OCCUR 1 Gate Wheels...

Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...

Страница 7: ...ed PARTS LIST 1 Tritek Controller 2 Rev Counter Housing 3 12 Volt DC Motor 4 Cam Lock 5 Manual Release Door 6 Foundation Plate 7 Height adjustment Nuts 8 LCD Interface 9 Joystick 10 USB Input 11 Trans...

Страница 8: ...e operator must not be installed It may be possible to reduce these forces by carrying out maintenance on the gate rail but if not then the operator must not be installed These forces can be measured...

Страница 9: ...e mode the gate may run freely down the slope and present a safety risk The gate should always be level This can be achieved by leveling the track using supports or spacers GATES ON A GRADIENT In circ...

Страница 10: ...carried out by a qualified electrician 3 Intercom gate station to operator consult with Intercom supplier for cable requirements 4 Keypad to operator consult with keypad supplier for cable requiremen...

Страница 11: ...pull the release pin until the lid is free The Lid can now be removed REMOVING THE LID 1 Open the manual release door and rotate the thumb wheel clockwise just until the gate begins to move 2 The thum...

Страница 12: ...e sure to remove any cement debris around the pinion gear Mount the operator above the flood level or if this is not possible build a small protective wall structure in front of the operator to divert...

Страница 13: ...rilling TEK screws through the slots in the rack 5 To attach additional rack slide the gate open and repeat the above procedures 6 After the rack has been attached use the Height Adjustment Nuts on th...

Страница 14: ...t that the gearbox be filled with oil before commissioning the operator Only use SAE75W 90 oil to refill Oil Level Screw Oil Plug 1 Push the gate to the fully closed position 2 Place the magnet on the...

Страница 15: ...s OUT3 this output must be connected to a Relay Module SA001 for switching Pillar lights Strobe warning lights Explore the LCD menus to adjust the many different options available RELAY this output is...

Страница 16: ...iffer ent options available LOOP this input is typically used in a business complex where a vehicle drives over a Ground Loop to trigger the gate open This input can be made inactive through the Time...

Страница 17: ...17 MAINS 220 240V AC HOUSE EARTH WARNING WHEN USING A SOLAR PANEL DISCONNECT THE TRANSFORMER NOT POLARITY SENSITIVE CHARGING SUPPLY OPTIONS SOLAR PANEL MAX 40V DC...

Страница 18: ...e accessed from this screen This shortcut will take you to the MAIN SETTINGS screen where all the controller features are available REMOTES DOWN South This shortcut will take you straight to the REMOT...

Страница 19: ...ultiple remotes are to be programmed continue to hold the Joystick UP North until all the remotes have been programmed to the operator Please refer to page 30 in this manual to learn more on Remote Se...

Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...

Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...

Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...

Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...

Страница 24: ...Normally Open N O Normally Open N O Normally Open N C Normally Closed Tamper Switch is CLOSED when the lid is removed PEDESTRIAN OPENING Keypad Receiver Keyswitch FULL OPEN Intercom STATUS LED Interco...

Страница 25: ...25 OUTPUT DEPENDANT ON VOLTAGE OF BATTERY FITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD of 100mA DACE Relay Module DACE Relay Module LIGHT ZONE BYPASS L N CONNECTION FOR RELAY MODULE...

Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...

Страница 27: ...ITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD 300mA DACE Relay Module DACE Relay Module WIRED TX RX ZONE BYPASS SIREN BELL BELL ALARM BUZZ GATE SYNC LIGHT ALARM BUZZ CONNECTING VARIOU...

Страница 28: ...RECEIVER GND TO TRITEK COM GND RECEIVER SAFETY BEAM A WARNING ONLY CONNECT BATT TO ONE MOTOR AS SHOWN OPERATOR CONTROL BOARD NO 1 OPERATOR CONTROL BOARD NO 2 TWO SYNCHRONISED OPERATORS CONNECTED TO ON...

Страница 29: ...If Open IR Reverse is enabled the gate will reverse back to the fully closed position if the Opening Safety Beam is blocked while the gate is opening If it is disabled the gate will only reverse back...

Страница 30: ...n the LCD screen during programming and engraving the remote number on the back of the remote This is helpful when you wish to delete a lost stolen remote Add Remotes No groups If a new group has not...

Страница 31: ...uard in attendance It is far less likely that unknown remotes are acci dentally programmed on to the controller Edit Group The TRITEK uses a grouping system for managing remote users This provides a l...

Страница 32: ...osition This is useful if a Pedestrian Trigger button is located some distance away from the gate such as on an intercom inside the building and allows the pedestrian to walk to the gate before it sta...

Страница 33: ...nabled this function will activate the controller s alarm output if any of the Safety Beams are blocked for a period longer than the time set in Ambush IR Timer when the gate is in the open ing positi...

Страница 34: ...is lost the magnetic lock will automatically unlock Magnetic locks are not suitable for use with solar powered systems Magnetic locks draw large amounts of power which will significantly reduce the nu...

Страница 35: ...to be deleted can be entered manually or the controller can be dialled via the phone while this function is open to automatically delete the number Delete Num By ID Cell phones that are no longer allo...

Страница 36: ...Any users added after the users were last saved onto the USB Flash Drive or Android device will be lost with this operation Save Settings This feature will save only the gate settings it excludes the...

Страница 37: ...e premises by a domestic worker With Time Manager you can disable any of the 8 Inputs INF CLS INF OPN LCK STP TRIG PED LOOP C LGHT or TAMPER at times you do not wish for that input to be used It is fo...

Страница 38: ...y Monthly and finally Weekly Set Start and Stop Day Time and Date Each period requires Start and Stop inputs Depending on the Type of Period this function will request days of the week hours minutes m...

Страница 39: ...exert on the gate while opening Anti Crush Gap 0 0 5m This is a safety feature to prevent the entrapment of people or animals by the gate while closing By enabling this feature the controller will see...

Страница 40: ...s speed should be high enough that the gate does not stall while closing but slow enough that the gate does not stop abruptly when reaching the fully closed position Close Crawl Distance Adjusts the C...

Страница 41: ...ion and during the Beam Reverse modes Slow Close Speed Adjusts the speed that the operator will run at when running in Slow Speed in the closed direction The operator runs in Slow Speed when programmi...

Страница 42: ...irmly in place and are not hanging loose Check that the Marker Magnet on the gate is tight and not moving If it is moving it must be tightened and the gate limits must be reprogrammed SERVICE SCHEDULE...

Страница 43: ...AUTO LEARN MODE EXITED The Auto Learn time expired or the user manually exited Auto Learn mode that was previously enabled SAVING FILE A file is being saved to the USB device LOADING FILE A file is b...

Страница 44: ...ound under Gate Setup on the LCD screen and adjust the opening and or closing forces WARNING MESSAGES MESSAGE DESCRIPTION TRIGGER The operator received a trigger signal PEDESTRIAN The operator receive...

Страница 45: ...tivate it again MOTOR FUSE BLOWN The controller has detected that the main motor fuse is blown Check to see if blown and replace this with an equivalent 20A fuse Check that the fuse contacts are free...

Страница 46: ...k The physical device used to navigate the menu on the controller LCD Screen The graphics screen display on the controller Loop Detector Detects when a vehicle drives over it to trigger the gate open...

Страница 47: ...nd the end stop Rack A length of gear attached to the gate which is driven by the pinion gear Rail The steel bar fixed to the ground along which the gate runs Receiver Receives a signal from a Remote...

Страница 48: ...troller Input Voltage 12V 24V AC or 17V 44V DC Motor Voltage 12V 24V DC Motor Supply Battery 12 24V or Transformer driven Battery Charger Intelligent multi stage charger with automatic shutdown curren...

Страница 49: ...sing through it It is the user s responsibility to ensure that there are no objects animals or people that could be damaged or injured near the gate prior to operating it The user must at all times be...

Страница 50: ...espective remote number label the remotes Remote button numbers and the functions assigned to each see pg 30 Cell phone User numbers see GSM Settings on pg 35 Cell PUK numbers associated to the operat...

Страница 51: ...51 NOTES...

Страница 52: ...using components not tested passed or authorised by DACE This warranty does not cover any Acts of God including lightning hail water power surge insect damage corrosion the transport or costs associat...

Отзывы: