SITE LAYOUT
GATE PULL & RUNNING FORCES
1.
Intercom Gooseneck
2.
Catch Bracket
3.
Close Safety Beam
4.
End Stop
5.
Exit Loop
6.
Isolator Switch
7.
Marker Magnet
8.
Open Safety Beam
9.
Guide Rollers
10.Pillar Light
1
9
8
5
6
7
2
3
4
10
The gate Pull and Running Forces must be
measured before installing the operator. Should
the measured forces exceed those in the table
below, then the operator must not be installed.
It may be possible to reduce these forces by
carrying out maintenance on the gate & rail but
if not, then the operator must not be installed.
These forces can be measured using a fishing or
luggage scale (see figure alongside)
Pull Force
: place the gate in the fully open/closed position and pull on the scale until the gate starts moving. The
value showing on the scale at the point that the gate starts moving is the Pull Force kgf.
Running Force
: this is the maximum value read while the gate is moving before coming to the fully open position.
4
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...