Two options for power supply:
1.
Option 1 (Recommended):
Low voltage supply 14
-
24V AC via transformer placed in the house, max 50m from operator with 3 core
1.5mm
2
(Live, Neutral & Earth).
2.
Option 2:
High voltage mains supply connected to a 220V/240V AC Double Pole Isolator switch, mounted within 1.5m of
the operator connected to the transformer inside the operator. Isolator may not be obscured by the gate
when in open position. Option 2 should be carried out by a qualified electrician.
3.
Intercom gate station to operator (consult with Intercom supplier for cable requirements)
4.
Keypad to operator (consult with keypad supplier for cable requirements)
5.
CLOSING Infrared beams to operator. Highly recommended for safe operation (4 core 0.5mm
2
multi
-
stranded
cable)
6.
OPENING Infrared beams to operator. Highly recommended for safe operation (4 core 0.5mm
2
multi
-
stranded
cable)
7.
Exit Loop to operator (1 core
-
consult with loop detector supplier for cable requirements)
CABLE RECOMMENDATIONS
3
1
2
4
7
5
6
•
ALL CABLES SHOULD BE PLACED IN CONDUIT
•
THERE SHOULD BE NO CABLE JOINTS INSIDE THE
CONDUIT
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...