BEAM SETTINGS
The use of Safety Beams on all installations is recommended.
To prevent accidents, Safety Beams must be used when enabling Auto Close.
The controller automatically detects when Safety Beams are connected and holds these in memory. If the
beams are removed and not replaced, it is necessary to run a Reset Beams (see below). This function will
detect the beams are missing and remove them from memory. If this is not done, they will remain in
memory and the controller will believe there to be “faulty” beams in place.
Beams Auto Close
This feature closes the gate automatically as soon as an object has passed through the beams.
Beams AC Time
This feature extends the delay after an object has passed through the beams until the gate closes. The
delay can be extended from 1 to 3600 seconds.
Beams AC Reverse
Only optional if Beams Auto Close is active. If Beams AC Reverse is enabled, the gate will slowly reverse
back to the open position if it was closing when the beams are blocked. If disabled, the gate will only
reverse back the programmed Back Off Distance.
IRBC Is Also IRBO
With this function enabled the Closing Beam will function as both Opening and Closing Safety Beams.
Close IR Reverse
If Close IR Reverse is enabled, the gate will reverse back to the fully open position if the Closing Safety
Beam is blocked while the gate is closing. If it is disabled, the gate will only reverse back the programmed
Back Off Distance (see below).
Open IR Reverse
If Open IR Reverse is enabled, the gate will reverse back to the fully closed position if the Opening Safety
Beam is blocked while the gate is opening. If it is disabled, the gate will only reverse back the pro-
grammed Back Off Distance (see below).
Back Off Distance
This function allows for the setting of a back off run distance of between 0.06
-
3m. See Open & Close IR
Reverse above.
Self Test Mode
If enabled, the controller will test the Safety Beams before closing the gate. This prevents accidental
closure of the gate on an object should the beams be faulty.
Only compatible with DuraOptics Wireless Safety Beams (with dipswitch settings).
Test Beam
When enabled, the controller will run a test on the Safety Beams to see if they are functioning properly.
Only compatible with DuraOptics Wireless Safety Beams (with dipswitch settings)
.
Reset Beams
The controller automatically detects when beams are connected to the system. Once detected, the
beams cannot be disabled unless the Reset Beams function is activated
.
CONTROL BOARD FUNCTIONS
Note the following functions on the TRITEK menu
:
Help
To get help on any of the onboard functions, move the cursor to the specific icon for which more
information is required. If the cursor is left standing on the same icon for more than six seconds, a help
screen will automatically appear. To exit the help screen move the cursor again.
Undo
The undo function will restore all the settings of the controller to six hours prior. This is useful if settings
were changed but it is necessary to revert back to the original settings.
Note
: All changes made in the last
six hours will revert back and not just the last item that was changed!
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...