DACE RT25/50 Скачать руководство пользователя страница 4

4

 

  

 

 

 

 

DACE is a proven leader in the manufacturing of automatic gate & garage operators and strives to manufacture 
high quality products using the latest technology. We are constantly working on upgrading our products to bring 
you, our clients, products of the finest quality. 

 

We strongly recommended using the services of an experienced gate installer to install your gate opera-
tor but if you intend installing the operator yourself, the manual must be read carefully before any 
installation begins.

 

While we have taken all reasonable steps to ensure that your gate operator is safe to install and use, it must be 
noted that your gate is a heavy moving piece of equipment and can cause serious damage or injury if it strikes an 
object or person. Your gate operator has built in electronic collision sensing which will make the gate stop and 
reopen if it strikes an object. This does mean however, that the gate will actually strike the object before it stops. 
It is because of this that we strongly recommended that DuraOptics Safety Beams are installed to reduce the risk 

of the gate striking an object. 

 

The installation of beams does not guarantee that the moving gate will not strike an object in it’s path.

 

Check the following items before installing the operator:

 

 

That the rail is level – the gate must not move on its own at any stage (discuss options available to you with 
your supplier if the rail is not level).

 

 

That the wheels are turning freely and are not jammed.

 

 

That the gate is not bent or bowed in any way.

 

 

That the rail has sufficient end stops so that the gate can never run off the end of the rail.

 

 

That the portal is constructed in such a way that the gate can not fall over.

 

 

That the top rollers are turning freely and are not jammed.

 

 

That the anti lift device is sufficient in order to stop the gate from being lifted off the rail.

 

 

That the gate mass or start

-

up force does not exceed the maximum as stated in the specifications.

 

 

That the gate does not jam in the catch bracket when closing or opening. 

 

 

The gate must not exceed the maximum number of operations stated in the specifications.

 

 

Extreme care should be taken when automating a gate that is fully cladded, as wind resistance can cause the 
gate to not close properly.

 

Only when all the above points are satisfactory should you go ahead with installing the gate operator. If a gate 
causes damage or injury the installer of the equipment may be held liable. 

 

DO NOT CONNECT MAINS VOLTAGE DIRECTLY TO THE CONTROLLER

 

 

If you intend to run AC directly from the building mains supply to the transformer, the wiring should be 
done by a qualified/registered electrician. This is a legal requirement and failure to do so may lead to  
non

-

compliance of property or law suits against the property owner in the event of an accident.

 

 

When running mains supply to the gate, it is recommended that you contact your local E.C.A. (Electrical 
Contractors Association) in order to obtain the legal wiring regulations relevant to the region in which you 
live.

 

 

Electrical shock can occur while installing this equipment

 

 

Injury or death by electrocution may lead to law suits against the installer/homeowner.

 

 

All wiring must be run in conduit. The supply wires must be run separate to any other wiring. 

 

 

Underground mains supply must be run in armoured cable. 

 

 

Under no circumstances may Communication cable, Ripcord or Cabtyre be used for 220V/240V mains      
connections.

 

 

Ensure that all electrical power is switched off before any electrical connections are made.

 

 

Do not open, tamper or modify any of the electronic components of this equipment in any way.

 

 

Do not attempt to repair the equipment, this should only be done by a qualified DACE technician.

 

 

DACE will not be held liable for any accident / incident resulting in damage, injury or death ensuing from the 
incorrect installation of the automatic gate operator.

 

 

Although these operators have built

-

in collision sensing, substantial damage can still occur. For this reason 

DuraOptics Safety Beams should be used on all installations.

 

 

For safety reasons, the Ultima RT 25/50 will only close at the maximum speed of 50 meters per minute if 
there are safety beams connected to the operator.

 

 

Do not allow children to play near or with any gate, gate operator or remote control.

 

 

It is the responsibility of the installer to ensure that the gate is in good working condition before automating 
the gate.

 

Continues……...

 

INTRODUCTION & RECOMMENDATIONS

 

Содержание RT25/50

Страница 1: ...INSTALLATION USER MANUAL RT25 50 Regular Traffic 12V 24V 25 50m per min 500 300kg HT18 36 High Traffic 12V 24V 18 36m per min 600 300kg Ver 1 01 Proudly manufactured by www dace co za...

Страница 2: ...ams Relay Output 20 11 2 External Radio Receiver Loop Detector 21 11 3 Closing Safety Beam FET Output Relay Output 22 11 4 Opening Safety Beam FET Output Relay Output 23 11 5 Connecting Common Externa...

Страница 3: ...anual Take Careful Note Information that may affect the operator or function in a way you did not expect Good Idea Following this instruction might assist in the future or help with the installation W...

Страница 4: ...care should be taken when automating a gate that is fully cladded as wind resistance can cause the gate to not close properly Only when all the above points are satisfactory should you go ahead with i...

Страница 5: ...on of the equipment There are a number of areas that may cause entrapment which could lead to injury ULTIMA TECHNICAL SPECIFICATIONS continued AREAS WHERE INJURY OR ENTRAPMENT CAN OCCUR 1 Gate Wheels...

Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...

Страница 7: ...ed PARTS LIST 1 Tritek Controller 2 Rev Counter Housing 3 12 Volt DC Motor 4 Cam Lock 5 Manual Release Door 6 Foundation Plate 7 Height adjustment Nuts 8 LCD Interface 9 Joystick 10 USB Input 11 Trans...

Страница 8: ...e operator must not be installed It may be possible to reduce these forces by carrying out maintenance on the gate rail but if not then the operator must not be installed These forces can be measured...

Страница 9: ...e mode the gate may run freely down the slope and present a safety risk The gate should always be level This can be achieved by leveling the track using supports or spacers GATES ON A GRADIENT In circ...

Страница 10: ...carried out by a qualified electrician 3 Intercom gate station to operator consult with Intercom supplier for cable requirements 4 Keypad to operator consult with keypad supplier for cable requiremen...

Страница 11: ...pull the release pin until the lid is free The Lid can now be removed REMOVING THE LID 1 Open the manual release door and rotate the thumb wheel clockwise just until the gate begins to move 2 The thum...

Страница 12: ...e sure to remove any cement debris around the pinion gear Mount the operator above the flood level or if this is not possible build a small protective wall structure in front of the operator to divert...

Страница 13: ...rilling TEK screws through the slots in the rack 5 To attach additional rack slide the gate open and repeat the above procedures 6 After the rack has been attached use the Height Adjustment Nuts on th...

Страница 14: ...t that the gearbox be filled with oil before commissioning the operator Only use SAE75W 90 oil to refill Oil Level Screw Oil Plug 1 Push the gate to the fully closed position 2 Place the magnet on the...

Страница 15: ...s OUT3 this output must be connected to a Relay Module SA001 for switching Pillar lights Strobe warning lights Explore the LCD menus to adjust the many different options available RELAY this output is...

Страница 16: ...iffer ent options available LOOP this input is typically used in a business complex where a vehicle drives over a Ground Loop to trigger the gate open This input can be made inactive through the Time...

Страница 17: ...17 MAINS 220 240V AC HOUSE EARTH WARNING WHEN USING A SOLAR PANEL DISCONNECT THE TRANSFORMER NOT POLARITY SENSITIVE CHARGING SUPPLY OPTIONS SOLAR PANEL MAX 40V DC...

Страница 18: ...e accessed from this screen This shortcut will take you to the MAIN SETTINGS screen where all the controller features are available REMOTES DOWN South This shortcut will take you straight to the REMOT...

Страница 19: ...ultiple remotes are to be programmed continue to hold the Joystick UP North until all the remotes have been programmed to the operator Please refer to page 30 in this manual to learn more on Remote Se...

Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...

Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...

Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...

Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...

Страница 24: ...Normally Open N O Normally Open N O Normally Open N C Normally Closed Tamper Switch is CLOSED when the lid is removed PEDESTRIAN OPENING Keypad Receiver Keyswitch FULL OPEN Intercom STATUS LED Interco...

Страница 25: ...25 OUTPUT DEPENDANT ON VOLTAGE OF BATTERY FITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD of 100mA DACE Relay Module DACE Relay Module LIGHT ZONE BYPASS L N CONNECTION FOR RELAY MODULE...

Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...

Страница 27: ...ITTED ENSURE ALL EXTERNAL DEVICES ARE CORRECTLY RATED MAX LOAD 300mA DACE Relay Module DACE Relay Module WIRED TX RX ZONE BYPASS SIREN BELL BELL ALARM BUZZ GATE SYNC LIGHT ALARM BUZZ CONNECTING VARIOU...

Страница 28: ...RECEIVER GND TO TRITEK COM GND RECEIVER SAFETY BEAM A WARNING ONLY CONNECT BATT TO ONE MOTOR AS SHOWN OPERATOR CONTROL BOARD NO 1 OPERATOR CONTROL BOARD NO 2 TWO SYNCHRONISED OPERATORS CONNECTED TO ON...

Страница 29: ...If Open IR Reverse is enabled the gate will reverse back to the fully closed position if the Opening Safety Beam is blocked while the gate is opening If it is disabled the gate will only reverse back...

Страница 30: ...n the LCD screen during programming and engraving the remote number on the back of the remote This is helpful when you wish to delete a lost stolen remote Add Remotes No groups If a new group has not...

Страница 31: ...uard in attendance It is far less likely that unknown remotes are acci dentally programmed on to the controller Edit Group The TRITEK uses a grouping system for managing remote users This provides a l...

Страница 32: ...osition This is useful if a Pedestrian Trigger button is located some distance away from the gate such as on an intercom inside the building and allows the pedestrian to walk to the gate before it sta...

Страница 33: ...nabled this function will activate the controller s alarm output if any of the Safety Beams are blocked for a period longer than the time set in Ambush IR Timer when the gate is in the open ing positi...

Страница 34: ...is lost the magnetic lock will automatically unlock Magnetic locks are not suitable for use with solar powered systems Magnetic locks draw large amounts of power which will significantly reduce the nu...

Страница 35: ...to be deleted can be entered manually or the controller can be dialled via the phone while this function is open to automatically delete the number Delete Num By ID Cell phones that are no longer allo...

Страница 36: ...Any users added after the users were last saved onto the USB Flash Drive or Android device will be lost with this operation Save Settings This feature will save only the gate settings it excludes the...

Страница 37: ...e premises by a domestic worker With Time Manager you can disable any of the 8 Inputs INF CLS INF OPN LCK STP TRIG PED LOOP C LGHT or TAMPER at times you do not wish for that input to be used It is fo...

Страница 38: ...y Monthly and finally Weekly Set Start and Stop Day Time and Date Each period requires Start and Stop inputs Depending on the Type of Period this function will request days of the week hours minutes m...

Страница 39: ...exert on the gate while opening Anti Crush Gap 0 0 5m This is a safety feature to prevent the entrapment of people or animals by the gate while closing By enabling this feature the controller will see...

Страница 40: ...s speed should be high enough that the gate does not stall while closing but slow enough that the gate does not stop abruptly when reaching the fully closed position Close Crawl Distance Adjusts the C...

Страница 41: ...ion and during the Beam Reverse modes Slow Close Speed Adjusts the speed that the operator will run at when running in Slow Speed in the closed direction The operator runs in Slow Speed when programmi...

Страница 42: ...irmly in place and are not hanging loose Check that the Marker Magnet on the gate is tight and not moving If it is moving it must be tightened and the gate limits must be reprogrammed SERVICE SCHEDULE...

Страница 43: ...AUTO LEARN MODE EXITED The Auto Learn time expired or the user manually exited Auto Learn mode that was previously enabled SAVING FILE A file is being saved to the USB device LOADING FILE A file is b...

Страница 44: ...ound under Gate Setup on the LCD screen and adjust the opening and or closing forces WARNING MESSAGES MESSAGE DESCRIPTION TRIGGER The operator received a trigger signal PEDESTRIAN The operator receive...

Страница 45: ...tivate it again MOTOR FUSE BLOWN The controller has detected that the main motor fuse is blown Check to see if blown and replace this with an equivalent 20A fuse Check that the fuse contacts are free...

Страница 46: ...k The physical device used to navigate the menu on the controller LCD Screen The graphics screen display on the controller Loop Detector Detects when a vehicle drives over it to trigger the gate open...

Страница 47: ...nd the end stop Rack A length of gear attached to the gate which is driven by the pinion gear Rail The steel bar fixed to the ground along which the gate runs Receiver Receives a signal from a Remote...

Страница 48: ...troller Input Voltage 12V 24V AC or 17V 44V DC Motor Voltage 12V 24V DC Motor Supply Battery 12 24V or Transformer driven Battery Charger Intelligent multi stage charger with automatic shutdown curren...

Страница 49: ...sing through it It is the user s responsibility to ensure that there are no objects animals or people that could be damaged or injured near the gate prior to operating it The user must at all times be...

Страница 50: ...espective remote number label the remotes Remote button numbers and the functions assigned to each see pg 30 Cell phone User numbers see GSM Settings on pg 35 Cell PUK numbers associated to the operat...

Страница 51: ...51 NOTES...

Страница 52: ...using components not tested passed or authorised by DACE This warranty does not cover any Acts of God including lightning hail water power surge insect damage corrosion the transport or costs associat...

Отзывы: