46
GLOSSARY
Anti
-
Lift Device
Prevents the gate from being lifted off the gate rail.
Auto Close
The automatic closure of the gate, not requiring a trigger input.
Battery
Refers to either a 12V or 24V battery that powers the gate operator.
Beams Auto Close
(BAC)
The immediate closing of the gate after a vehicle or pedestrian has passed through the
Safety Beams, stopping the gate from running to the fully open position unnecessarily.
Catch Bracket
A locating bracket, mounted to the gate post, that holds the gate securely when in the
closed position. It can be used as part of an anti lift system or to lock the gate with a
padlock when not in operation.
Collision Sensing
The controller software responding to changes in current draw and operator run speed
as a result of the gate hitting an obstruction.
Condo Mode
Short for Condominium. See Multi User Mode
Controller
The circuit board containing the electronic components and software that controls the
gate operator.
End Stop
A metal device on the gate rail, used to prevent the gate from running off the gate rail in
both the open and closed positions.
Foundation Plate
The steel plate used to anchor the operator to a concrete slab.
Infrared Beams:
See Safety Beams
Intercom
Allows for two way communication between the gate and the house.
Joystick
The physical device used to navigate the menu on the controller.
LCD Screen
The graphics screen display on the controller.
Loop Detector
Detects when a vehicle drives over it to trigger the gate open (or closed).
MESSAGE
DESCRIPTION & SOLUTION
ENCODER
FAULT
The controller has detected an encoder fault.
Ensure that the controller is sitting properly on the controller base.
If a Tritek controller is being used on a older DACE product i.e. not an Ultima, check that the
encoder is plugged in correctly.
OPENING IR
BEAM FAULT
The beams Self Test function is active on the controller and has detected that the opening safety
beam is not functioning correctly.
Ensure the beams are compatible with the Self Test function. Only DACE compatible beams
can be used with this function.
Ensure the opening safety beams are powered up correctly
Check that the opening safety beams are not blocked.
If there are multiple beams in place, make sure there is no crosstalk between the different
sets of beams.
CLOSING IR
BEAM FAULT
The beams Self Test function is active on the controller and has detected that the closing safety
beam is not functioning correctly.
Ensure the beams are compatible with the Self Test function. Only DACE compatible beams
can be used with this function.
Ensure the closing safety beams are powered up correctly
Check that the closing safety beams are not blocked.
If there are multiple beams in place, make sure there is no crosstalk between the different sets
of beams
……..continued
Continues……...
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...