![DACE RT25/50 Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/dace/rt25-50/rt25-50_installation-and-user-manual_3129401030.webp)
30
AUTO CLOSE SETUP
To prevent accidents, Safety Beams must be used when enabling the Auto Close function.
Enable Auto Close
Enabling this function allows the gate operator to Auto Close. If the gate is obstructed and Safety Beams
are connected, the Auto Close Time delay will reset when the obstruction is removed.
Auto Close Time
This feature delays the closing of the gate when Auto Close is enabled. The delay can be set from 1
-
600
seconds. If beams are connected, the timer will reset each time the beams are blocked.
AC On Full Open
If enabled, the gate will Auto Close from the fully open position.
AC On Part Open
If enabled, the gate will Auto Close if it was stopped while still opening.
AC On Part Close
If enabled, the gate will Auto Close if it was stopped while it was closing.
Allow Party Mode
‘Party Mode’ is a feature which overrides Auto Close. By enabling the Allow Party Mode function, it is
possible to place the operator into Party Mode with the Trigger button on the remote.
REMOTE SETTINGS
Up to 1024 Remotes can be added to the TRITEK onboard Receiver.
The TRITEK controller uses Remote Grouping for managing remote access. All remotes must be pro-
grammed to a group for it to function. By default, all remotes will be programmed to the Master group,
Group 0, unless a new group is created. If groups have been created, the controller will prompt the user
to select the group into which the new remote must be programmed.
If Groups are being used, it is important to keep track of your remotes. This can be done by writing down
the remote number seen on the LCD screen during programming and engraving the remote number on
the back of the remote. This is helpful when you wish to delete a lost/stolen remote.
Add Remotes (No groups)
If a new group has not been created, the controller will prompt for a Program Method by which to add
the new remote/s.
First Method:
Teach Single Function to the Remote Button. This will program a single function to a
button. It begins at Function 1, which is Trigger, and scrolling left will run through all the available func-
tions up to 16. These include Pedestrian Trigger, Alarm Activate, Party Mode, Light Trigger etc.
Having selected the particular function required, the controller prompts to hold the Joystick Up (North)
and, while holding the joystick in this position, add the remote/s by pressing the button that is required
to perform the selected function.
Second Method:
Duplicate Group Functions to Remote. This will duplicate the functions already setup on
the existing remotes in Group 0 to the new remote now being programmed.
When selected, the controller prompts to hold the Joystick Up (North) and, while holding the joystick in
this position, the existing functions are duplicated onto the new remote by pressing any button on it. All
functions in Group 0 will be copied onto the new remote.
The default function settings for Group 0 are:
1.
Trigger
2. Pedestrian Trigger
3. No Function
4. No Function
5. Holiday Lockout
6. Alarm Activate
7. No Function
8. No Function
9. Alarm Activate
10. Party Mode
11. No Function
12. Light Trigger
13. No Function
14. No Function
15. Remote Joystick
The function number relates to the remote button number or
button configuration as illustrated.
Continues……...
1
= 1
2
= 2
3
= 1 + 2
4
= 4
5
= 1 + 4
6
= 2 + 4
7
= 1 + 2 + 4
8
= 8
9
= 1 + 8
10
= 2 + 8
11
= 1 + 8
12
= 4 + 8
13
= 1 + 4 + 8
14
= 2 + 4 + 8
15
= 1 + 2 + 4 + 8
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...