GATE SETUP
Setup Wizard
This function automatically programs the open and closed gate limits. The Setup Wizard will run auto-
matically after the first power up of a new operator or after a gate factory reset (see Use Factory
Settings). The Setup Wizard can be run anytime the limits need to be relearnt. Follow the prompts to
complete.
To run the Setup Wizard it is required that the Terms and Conditions are agreed to, these are available in
this manual. Ensure that these are read and understood as non acceptance will prevent the commission-
ing of the operator.
Safety Settings
Closing Force (10
-
100%)
This function sets the maximum torque that the gate operator will exert on the gate while closing. A
heavy gate, or one that does not move easily, will require a higher torque setting than a light gate.
This setting also determines the force the gate will exert on an object if it obstructs it’s path when
closing, referred to as Collision Sensing. If the setting is too high the gate will strike the object with
high force and may cause damage or injury to the obstructing object. If it is too low however, the
gate may stop as a result of small interferences such as a pebble or dirt on the track. It is important
to set the Closing Force to a level that suits the specific site when commissioning the operator.
Opening Force (10
-
100%)
This function is the same as Closing Force except that it sets the maximum torque that the gate oper-
ator will exert on the gate while opening.
Anti
-
Crush Gap (0
-
0.5m)
This is a safety feature to prevent the entrapment of people or animals by the gate while closing. By
enabling this feature the controller will see any trigger received as an Open trigger if the gate was
stopped within the Anti Crush Gap while the gate was closing. Only once the gate is outside the Anti
Crush Gap will the controller accept a Close trigger.
Dynamic Adjust (10
-
100%)
Dynamic Adjust is an additional safety setting to prevent the operator from exerting too much force
on an obstruction. While The Opening Force and Closing Force functions set a fixed maximum force
limit, this function automatically adjusts, as a percentage offset, from the current running force of
the gate while it is running. This means that any unexpected changes in force are detected sooner
than if the controller were to wait for the maximum force to be exceeded, as set in the Opening and
Closing Force settings. Dynamic adjustment is by default enabled but may be disabled in the Run
Profile menu.
Run Profile
During a standard open or close operation, the gate follows the running profile as indicated below. The
operator will increase the gate speed during the Ramp Up phase until it reaches its Running Speed. When
it approaches its end position, the gate will first Ramp Down and then Crawl until it reaches its end
position. Many of these speeds and distances may be adjusted to suit a specific installation. For instance,
in a high pedestrian traffic area it may be required to have longer Crawl distance while in a high security
area it may be required to have no crawling distance at all.
Continues……...
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...